OPEraTION
Settings
www.stiebel-eltron.com
WPL 15 IKS | WPL 25 IK |
9
Under the PARTY menu item, you can extend the day mode by a
few hours.
TEMPERATURES
Here you can check the heat pump system sensor temperatures,
comparing set with actual values, check the heating curve gap etc.
HEATING CURVES
Here you can select a heating curve each for heating circuit 1 and
heating circuit 2. Please note that the room temperature will only
remain constant irrespective of the outside temperature if the
correct heating curve has been selected for the relevant type of
building. Selecting the correct heating curve is therefore vitally
important.
HEATING PROG
Here you can adjust heating programs associated with heating
circuits 1 and 2 (see chapter „Settings / Heating programs“).
DHW PROGRAM
Here you select the times when the appliance will control DHW
heating using the set day value. At all other times, the appliance
controls DHW heating using the set night value (setback mode).
See chapter „Settings / DHW programs“).
COMMISSIONING
Note
The commissioning level (control level 3) may only be
altered by your qualified contractor.
Here the settings of control level 2 and the system-specific para-
meters need to be determined. Your heating contractor or our ser-
vice department can set the parameters at control level 3, which
is protected by code.
All parameters must be checked by your contractor or our service
department. All selected values should be entered into the rele-
vant column (system value) in the commissioning report.
4.5 Adjustments at control level 2
You can change the values under individual menu items, if requi-
red, by using the programming key and the rotary selector.
f
f
Follow the instructions in the following diagrams which illus-
trate the process step by step.
Note that the values can only be adjusted when the programming
indicator is illuminated.
f
f
Press the programming key again to save the altered set
values.
The values are saved when the programming indicator goes out.
If the programming indicator does not go out after saving the
value, this means that there are further values that can be set
under this menu item.
4.5.1 Room temperature, heating circuit 1
With menu item ROOM T HC1, you can select the set room tempe-
rature for day and setback mode for heating circuit 1. Changing
these parameters results in a parallel shift of the heating curve.
The actual room temperature can also be scanned, as soon as the
FE 7 remote control has been connected and allocated to heating
circuit 1.
ROOM T HC1
SET ROOM T DAY
SET ROOM T DAY
SET ROOM T NGT
SET ROOM T NGT
ACTUAL ROOM T
ROOM T HC1
BACK