OPEraTION
Settings
www.stiebel-eltron.com
WPL 15 IKS | WPL 25 IK |
13
TEmPEraTUrES
meaning
OUTSIDE
Outside temperature
ACT ROOM T FE7
Actual room temperature for heating circuit 1 (HC1) or heating circuit 2 (HC2)
(will only be displayed if the FE 7 remote control is connected)
SET ROOM T FE7
Set room temperature for heating circuit 1 or heating circuit 2
(will only be displayed if the FE 7 remote control is connected)
REL HUMIDITY
Relative humidity (will only be displayed if the FEK remote control is connected)
DEW POINT TEMP
Dew point temperature (will only be displayed if the FEK remote control is connected)
ACTUAL DHW T
Actual DHW temperature
SET DHW TEMP
Set DHW temperature
ACTUAL RTRN T
Actual heat pump return temperature for heating circuit 1
ACT HP FLOW T
Actual heat pump flow temperature
ACT NGT FLOW T
Flow temperature of electric emergency/booster heater
HTG CIRC ACT T
Actual heating circuit temperature for heating circuit 1
HTG CIRC SET T
Set heating circuit temperature for heating circuit 1 (HC1). Fixed temperature is displayed with set value control.
ACTUAL MIXER T
Actual mixer flow temperature for heating circuit 2
SET MIXER TEMP
Set mixer flow temperature for heating circuit 2
ACT BUFFER T
Actual buffer temperature
FIXED FLOW T
Set fixed temperature for heating circuit 1
SET BUFFER T
Set buffer temperature (Highest set value of heating circuits H1 and H2. Fixed temperature will be displayed for fixed temperature
control.)
DUAL-MODE HTG
Dual-mode point - central heating
DUAL-MODE DHW
Dual-mode point - DHW
SYST FROST PRO
System frost protection temperature
HEATING PRES
HEATING PRES
ACT VOLUME
Current flow rate [l/min]
MAX VOLUME
Flow rate for monitoring the defrost process [l/min]
STATUS HP 1
Status signal for "HP operation" and "HP fault"
STATUS HP 2
Status signal for "HP compressor�ON" and "defrost mode"
ST HP OPERATN
Heat pump operation ON/OFF
ST HP COMP
Compressor ON/OFF
ST HP FAULT
Refrigerant circuit fault ON/OFF (ON= fault, OFF = no fault)
ST HP DEFROST
Defrost mode ON/OFF
OUTPUT HP
Controller output signal for heat pump output control
INT PUMP RATE
Circulation pump output
HEAT AMOU DAY
Amount of compressor heat generated in heating mode since 0:00 h today.
TTL HEAT AMOU
Total amount of compressor heat generated in heating mode.
HEAT AMOU DAY
Amount of compressor heat generated in DHW mode since 0:00 h today.
TTL HEAT AMOU
Total amount of compressor heat generated in DHW mode.
TTL HEAT AMOU
Total amount of heat generated by the electric booster heater in heating mode.
TTL HEAT AMOU
Total amount of heat generated by electric reheating in DHW mode.