14 Manual mode
In the
Manual mode
menu, the operating mode of
all relays in the controller and in connected modules
can be adjusted.
all relays are displayed in numerical order, first those
of the controller, then those of the individual modu-
les connected. modules are listed in numerical order.
under the menu item
All relays...,
all relays can be
switched off (off) or set to automatic mode (auto)
at once.
off
= relay is switched off (manual mode)
auto = relay is in automatic mode
the operating mode can be selected for each indivi-
dual relay, too. the following options are available:
off
= relay is switched off (manual mode)
min. = relay active with minimum speed
(manual mode)
max. = relay active at 100 % speed (manual
mode)
auto = relay is in automatic mode
Note:
always adjust the operating mode back to
Auto
when the control and service work is
completed. otherwise normal operation
will not be possible.
adjustment channel Description
adjustment range / selection Factory setting
relays r1 ... X
operating mode selection
max, auto, min, off
auto
all relays...
operating mode selection for all
relays
auto, off
off
Manual mode
295931-36390-8667 SOM 8 plus_en.indb 71