st
eut
e T
echnol
ogies GmbH & Co. K
G
Brück
ens
tr
aße 91, 32584 Löhne, Germany
, www
.s
teut
e.c
om
//
RF I/O SW868/SW915/SW917/SW922-4E-2,2Ah
15 / 24
Montage- und Anschlussanleitung / Funkschalter
Mounting and wiring instructions / Wireless switch
Instructions de montage et de câblage / Interrupteur de radio
Istruzioni di montaggio e collegamento / Interruttore di radio
Instruções de montagem e instalação / Interruptor de rádio frequência
Инструкция по монтажу и подключению / Радио-выключатель
English
Technical data RF I/O
Applied standards
EN 60947-5-1; EN 61000-6-2, -6-3,
EN 61000-4-2, -4-20;
EN 301 489-1; EN 301 489-3;
EN 300 220-1; EN 300 220-2
Enclosure
98 x 64 x 37 mm ABS
Connection
connector M12 x 1, 4-pole
Suitable sensors
sensors: RF IS M8, RF IS M12, RF IS M18,
RF IS M30
Degree of protection
IP67 to IEC/EN 60529
Protocol
sWave®
Ambient temperature
-20°C … +65°C
Switching frequency
5 Hz
Standby current
60 µA
Voltage supply
Tadiran SL-760; system Li/SOCl2;
nominal voltage 3.6 V
Capacity
2.2 Ah
Frequency
868.3 MHz (EU) or 915.0 MHz (USA, Canada,
Mexico) or 917.0 MHz (Brazil) or
916.5 MHz (Japan)
Channel bandwidth
SW868: 480 kHz, SW915, SW917: 550 kHz,
SW922: 520 kHz
Transmission power
SW868, SW915, SW917: <25 mW
SW922: <1 mW
Data rate
66 kbps
Wireless range
SW868, SW915, SW917:
max. 450 m outside,
max. 40 m inside
SW922:
max. 150 m outside,
max. 20 m inside
Actuating time
min. 80 ms
Battery life
depending on the switching frequency and
number and type of sensors for 1000 trans-
fers/day and one inductive sensor approx. 300
days; for 1000 transfers/day and one mechan-
ical switch approx. 1400 days
Note
transmission of battery power
Wireless approval
EU: RED 2014/53/EU
USA:
FCC - XK5-RFRXSW915
Canada:
IC - 5158A-RFRXSW915
Mexico: IFT - RCPSTRF17-1886
Brazil:
ö
04172-18-06718
Japan: ARIB STD-T108: 204-610002
Technical data RF IS
RF IS M8 nb-ST
Material No. 1 different cable lengths
RF IS M30 nb-ST
Material No. 1 different cable lengths
RF IS M12 nb-ST
Material No. 1 different cable lengths
RF IS M18 nb-ST
Material No. 1 different cable lengths
Standards
EN 60947-5-2
Enclosure
brass-nickel, back cap PVC, black
Connection
plug-in connector M12 x 1, 4-pole
cable length 0.5; 1; 2; 5 or 10 m
Degree of protection
IP67 to IEC/EN 60529
Ambient temperature
-25°C … +70°C
Ui
75 VDC
Ie
0.2 mA
Ue
3 … 5 VDC
Switching distance
RF IS M8: sn 2 mm; sa 0 … 1.62 mm;
sr 1.8 mm … 2.2 mm
RF IS M12: sn 4 mm; sa 0 … 3.24 mm;
sr 3.6 mm … 4.4 mm
RF IS M18: sn 8 mm; sa 0 … 6.48 mm;
sr 7.2 mm … 8.8 mm
RF IS M30: sn 15 mm; sa 0 … 12.15 mm;
sr 13.5 mm … 16.5 mm
Hysteresis
approx. 10%
Repeatability
<5%
Mounting
non-flush
Switching frequency
see RF I/O
Correction factors
Steel (St37) = 1; V2A approx. 0.7; Ms approx.
0.5; Al approx. 0.5; Cu approx. 0.4
Actuators
RF IS M8: steel plate 8 x 8 x 1 mm, FE 360
RF IS M12: steel plate 12 x 12 x 1 mm, FE 360
RF IS M18: steel plate 24 x 24 x 1 mm, FE 360
RF IS M30: steel plate 45 x 45 x 1 mm, FE 360
Note
The sensor may only be used in combination
with an Ex RF 96 ST, RF 96 ST or RF I/O;
2 mounting nuts are provided.
Errata and technical changes reserved.