
Assembling main parts
Operation & maintenance instructions (Version H)
44
SKY-200/250
Flush mounted type:
At a height of 4 ft / 1250 mm (see
) the value should be approx. 4,4V.
Surface mounted type:
At a height of 3 1/4 ft (1020 mm) the value should be approx. 4,4V.
- Inclinometer P1 (red) on terminal 62 and 63.
- Inclinometer P2 (yellow) on terminal 72 and 73.
- Inclinometer P3 (green) on terminal 82 and 83.
- Inclinometer P4 (blue) on terminal 92 and 93.
13.
Take inclinometer P1 (red) as a reference and adjust the other three within 0.05 Volt
accuracy by rotating the inclinometer (this is best done with two persons).
4.5.3
Mounting to the floor
1.
Make sure that the tracks are positioned at the correct spot. Check if the distance
between the tracks is correct. If a jacking beam (FL120 or FL160) is to be used on
the lift, then the distance between the tracks must be 43" (1100 mm) minimal and
parallel within 0.4" (10 mm).
2.
Check that the tracks are aligned (see
Figure 4.8 ’Distance between the tracks’ on
).
Figure 4.14
Inclinometer values
Summary of Contents for SKY-200
Page 152: ...Operation maintenance instructions Version H 152 SKY 200 250 ...
Page 153: ......