Assembly
Operation & maintenance instructions (Version H)
43
SKY-200/250
4
9.
Raise the lift.
If necessary use the switches MS and UP on the PCB in the controlbox. Next lower
the lift and press the lowering button for 20 more seconds to bleed the air from the
hydraulic cylinders.
10.
Flush mounted type:
Raise the lift to a height of about 4 ft (1250 mm) and lower in into the safety locks.
Surface mounted type:
Raise the lift to a height of about 3 1/4 ft (1020 mm) and lower in into the safety locks.
11.
In this position, check the setting of the inclinometers from the fault code display in
the controlbox.
The inclinometers are factory-set but setting can change during transport. If one dot
is shown, the adjustment is accurate within 1/2" (12 mm) and if 2 dots are shown,
the adjustment is accurate within 1/4" (6 mm). The lift should already be operational
when only one dot is shown.
12.
Measure if required the inclinometer values.
Use a digital multimeter and set the measuring range to 20 VDC. Measure the value
of each inclinometer.
Figure 4.13
Measuring the inclinometer values