9
AlphaCom XE - Installation, Configuration & Operation
A100K10805
Unpacking and Installing Hardware
2.2
Remove all hardware from the packing boxes and inspect each item to
ensure that they have not been damaged during shipping. In addition,
check that the packing boxes contain all the items you ordered. If you
discover or suspect any damage, contact your distributor immediately.
2.2.1 Installing the AlphaCom XE1 cabinet
More information is found in Datasheet A100K10798
The cabinet should be mounted on a shelf or in a 19” rack. It contains
one AMC-IP processor board only. The server includes a power board.
● All cables are terminated to connectors at the rear of the cabinet.
Two RJ-45 Ethernet terminals are used for IP LAN, WAN, Internet
●
and AlphaNet IP communication.
The serial ports with RS232 and RS422 interfaces are used for
●
connecting to equipment using these protocols.
The unit is powered from a 90-270 VAC via a 5 VDC power supply at
●
4 W maximum.
2.2.2 Installing the AlphaCom XE7 cabinet
More information is found in Datasheet A100K10799
The cabinet can be wall or shelf mounted or mounted in a 19” rack. It
has room for installation of one AMC-IP processor board and up to 6
feature boards. The server also includes a power board and a cooling
fan.
All cables are terminated to connectors on the backplane.
●
The two-pair star wired intercom cables are connected using
●
pluggable screw connectors.
Two RJ45 Ethernet terminals are used for IP LAN, WAN, Internet and
●
AlphaNet IP communication.
The serial ports with RS232 and RS422/485 interfaces are used for
●
connecting to equipment using these protocols.
● The two NO switches on the RCI connectors can execute
programmable functions.
The 12 RCOs are connected to optional MRBD relay boards and can
●
be programmed to execute functions such as door control.
Connectors 5 and 6 on the first ASLT line board are enabled for
●
program distribution. Additional programs can also be connected
to individual ASLT ports via the interface board FBSAR, with 6
programs per board.
If line points 5 and/or 6 are to be used as subscriber line points,
follow the connection procedure for AlphaCom XE7 in section 2.2.9.
The server is normally powered from the mains via a 24 VAC
●
transformer. The 6 A type 203 0010 260 can serve up to 24
subscribers, while the 11 A type 203 0010 270 is needed for a full
cabinet of 36 subscribers.
Battery backup power is connected to the 24 VDC input plug.
●
The ground terminal is connected to the cabinet.
●
The jumper is used to provide galvanic connection between the
cabinet and 0V (DC-GND) or isolation from 0V (AC-GND). AC-GND
is only used on marine vessels.
Serial Port 1
Serial Port 0
Eth 0
Eth 1
5 VDC
1
1
1
230 VAC
5 VDC
MAINS
AlphaCom XE7
AlphaCom XE7
36
31
1
P5
P6
N1
N5
N4
N2
N3
C
C
D
D
24V DC
Out
24V AC In
+
24V DC
In
+
_
_
Program level
RCO 1 - 6
1
RCO 7 - 12
P6
P5
RCI 2
RCI 1
Eth 0
Eth 1
Serial Port 0
Serial Port 1
USB
485 422
1
12
6
5
18
24
30
7
13
19
25
1
2
3
230VAC
24VAC
MAINS
24VDC
A B C D
MRBD
7 . . . . 1 2
MRBD
1 . . . . 6
1
2
A C -
G N D
D C -
G N D
Alpha C om XE7
Alpha C om XE7
1 2 3 4 5
STENTOFON
VMP-
D619
*
#
1
2
3
4
5
6
7
8
9
0
C
M
V I N G T O R