20
A100K10805
AlphaCom XE - Installation, Configuration & Operation
EVENTS
AUDIO MESSAGING
User Event with tone
9 533
X
Recording from station
8180
X
User Event silent
9534
X
Stored Voice message
8181-8182
X
Two-step Event trigger
9535
X
PA activation, multi-step
765
X
Digit Event trigger
9545
X
PA activation, one-step
9084-9088
X
PA to global group
9101
X
Recorded message to group 1
9184
X
Auto-attendant
9550
X
* 805-806 in XE7
** Default is 6 pr OFF
***
Not in Auto-load
System maintenance
2.5.6
System maintenance access is restricted to the Super User station
connected to physical line number 1. This station has Class of Service
16,
All Functions
.
FEATURES FOR SUPER USER STATION
Feature
No.
CoS1
CoS15
Set volume
783
Set time and date
785
Station ID (dir physical nos.)
789
X
AlphaCom IP configuration
7810
Install backup from EPROM
7819
Store backup to EPROM
7820
Reset board error
7871
AGA audio test
7872
Set access to feature
7873
Tone test
7885
Block alarm input
7888
Unblock alarm input
7889
Control room stations
2.5.7
Stations used for control rooms such as guard locations in prisons,
buildings, parking facilities, etc. may be a dedicated Control Room
Master (CRM) station or a normal master station with display.
CONTROL ROOM STATION FEATURES
Feature
No.
CoS1
CoS15
CONTROL ROOM STATIONS
Call Request, Alarm
622
X
Call Request, Ordinary
623
X
Call Request, Alarm
624
X
Call Request, Ordinary
625
X
Cancel Call Request
626
X
Call request, Alarm
627
X
Call Request, Ordinary
628
X
Call Request transfer
7870
X
Acknowledge Priority Mail
7882