53
AlphaCom XE - Installation, Configuration & Operation
A100K10805
9101:
Recall to global group 1 (for AlphaNet)
-
More recall numbers can be added from AlphaPro if required:
● In the
Directory & Features
window, select
Insert
Select
●
Group Call w/Recall - 113
from the
Feature
drop-down list
Enter the local group number in the
●
ID
field
Enter any free directory number and an appropriate display text in
●
the
Directory Number
and
Display Text
fields.
The recall function can also be activated via a two-step operation using
feature code 765:
Dial 765 + group number.
●
User interface
9.3.2
Using the recall function from an intercom station
1. Dial the
recall number
(e.g. 9084 or 765+84)
2. Press the
M-key
to record a message
3. Release the
M-key
to listen to the recording
4. Press
8
to dispatch the message or:
Press the
-
M-key
to make a new recording
Press
-
7
to repeat the message
Press the
-
C-key
to cancel the message
Using the recall function from a telephone
1. Dial the
recall number
(e.g. 9084 or 765+84)
2. Press the
*-key
to record a message
3. Press the
#-key
to stop the recording and listen to the message
4. Press
8
to dispatch the message or:
Press
-
*
to make a new recording
Press
-
7
to repeat the message
Hang up
-
to cancel
Optional settings
9.3.3
The recall user interface and the recall attributes can be altered by
modifying parameter 2 (set in AlphaPro) of the recall directory number.
By default, this parameter has value 0.
RECALL OPTIONS
Value
parameter 2
Function
1
After playback to the group has finished, the group call and the initiator
station will proceed to normal Group Call mode, and can use the M-key to
talk into the group
2
If the initiator station disconnects during playback to the group, the message
is terminated immediately
8
The initiator station will not listen to the playback to the group
32
The message is dispatched when pressing the C-key or hanging up (no need
to confirm by pressing 8)
128
There will be no gong before the group call
256
The group is a global group call
512
There is no need to use the M-key during the recording
Parameter 2 can be modified to change the recall user interface and
different options can be combined.
Example: