Integrating FMC controllers in CAN networks
Operating manual FMC200 controller
E-43
Baud rate
The following baud rates are available:
Baud rate: 125 Kbps - 1 Mbps
The baud rate is configured using the programming software EasyMo-
tion Studio.
INFORMATION
Please note that the baud rate has to be the same for all the FMC con-
trollers connected in the network.
Termination
The first and last node of the CAN network has to be terminated with
a termination resistor of 120 Ω. The resistance is connected using the
DIP switch of the respective FMC controller (see see “Integrating the
FMC controller in the CAN network” starting from page 44).