3.3. Firmware Update
The IDU’s firmware, including software running on the embedded microprocessor
as well as the FPGA-based modem and related signal processing, can be remotely
updated. An outline of the instructions for updating firmware are as follows:
1) Setup TFTP server and associated firmware upgrade files. Detailed instructions
are provided below for installing (freeware) Solarwinds TFTP server on a standard
PC. The operator may also use an existing TFTP server if one is available.
2) Establish Ethernet connection between the computer hosting the TFTP server
and the IDU (locally or via a network). 3) Execute upgrade via the IDU’s web GUI
interface.
3.3.1. Step 1 – Setting Up Solarwinds TFTP Server
These instructions assume that the (freeware) Solarwinds server is to be installed
on an external PC.
•
Ensure all firewalls are switched off on the external PC.
•
Install Solarwinds TFTP server on the external PC. The TFTP software is
available for download at
http://www.solarwinds.com/downloads/
Look for
“Free TFTP Server on the Solarwinds web page and download.
•
Once installed on the external PC, start the TFTP server application, as
shown in Figure 32.
Summary of Contents for SM Cirius LM
Page 21: ...Cirius LM User Manual 2016 Page 21 Figure 11 Web GUI Login Page ...
Page 27: ...Cirius LM User Manual 2016 Page 27 Figure 14 Web GUI Modem Tab ...
Page 29: ...Cirius LM User Manual 2016 Page 29 Figure 15 Web GUI Link Quality Tab ...
Page 31: ...Cirius LM User Manual 2016 Page 31 Figure 16 Web GUI Telco Lines Tab shown T E4 ...
Page 33: ...Cirius LM User Manual 2016 Page 33 Figure 17 Web GUI Ethernet Tab ...
Page 35: ...Cirius LM User Manual 2016 Page 35 Figure 18 Web GUI ODU Tab ...
Page 38: ...Cirius LM User Manual 2016 Page 38 Figure 20 Web GUI Event Log Tab ...
Page 72: ...Cirius LM User Manual 2016 Page 72 ...