7. 1+1 Protection
7.1. Introduction
The radio in its standard configuration is an unprotected (1+0) IDU with a single N-
type connector interface to connect to a single ODU. An optional hot standby
protected (1+1) mode configuration is available, whereby two identical ODUs, a
primary and a secondary, are connected to a single IDU via two N-type connector
interfaces. The purpose of 1+1 protection is to minimize link outages by protecting
against ODU hardware failure by providing automatic switching to a standby
secondary ODU in the case of fault detection in the primary ODU. Note that this
feature is only available on the IDU.
7.2. 1+1 Switch Protection Operation
In a 1+1 redundant configuration, two identical ODUs, a primary and a secondary,
are connected to a single IDU. The primary ODU carries network traffic while the
secondary ODU remains in hot standby. In the event of fault detection in the
primary ODU, the IDU will automatically switch traffic to the hot standby secondary
ODU. The IDU will switch the transmit path only, the receive path only, or both,
depending on the nature of the failure. (Switching only the failed path avoids link
disruption in the nonfailed direction.) The IDU monitors the following parameters to
make this switch decision:
•
Near-side IDU Rx demodulator lock
•
Far-side IDU Rx demodulator lock
•
Near-side primary and standby ODU Rx RSSI
•
Far-side primary and standby ODU Rx RSSI
•
Presence or absence of IDU-ODU commands and status link
•
Presence or absence of far-side telemetry channel data
During normal operation, the primary ODU will operate normally and the standby
ODU will have its transmitter muted. Both receivers will be operational. Thus, at
each end of the link, both the primary and the standby ODU will receive
transmissions from just the primary ODU transmitter on the opposite end of the
link. The transmitter of the standby ODU is disabled until a failure is detected.
Three general scenarios are addressed by the protected mode operation:
1)
Receive Path Failure
: In the event of a receive path failure, the receive path is
switched to the standby ODU. The transmit path is unaffected.
Summary of Contents for SM Cirius LM
Page 21: ...Cirius LM User Manual 2016 Page 21 Figure 11 Web GUI Login Page ...
Page 27: ...Cirius LM User Manual 2016 Page 27 Figure 14 Web GUI Modem Tab ...
Page 29: ...Cirius LM User Manual 2016 Page 29 Figure 15 Web GUI Link Quality Tab ...
Page 31: ...Cirius LM User Manual 2016 Page 31 Figure 16 Web GUI Telco Lines Tab shown T E4 ...
Page 33: ...Cirius LM User Manual 2016 Page 33 Figure 17 Web GUI Ethernet Tab ...
Page 35: ...Cirius LM User Manual 2016 Page 35 Figure 18 Web GUI ODU Tab ...
Page 38: ...Cirius LM User Manual 2016 Page 38 Figure 20 Web GUI Event Log Tab ...
Page 72: ...Cirius LM User Manual 2016 Page 72 ...