Instruction Manual
29
Getting Started
Name
This parameter sets the Service Set Identifier (SSID) for the access point in the QPM Expert
Alpha controller.
The maximum number of case sensitive, alphanumeric (ASCII) characters is 32. It is
recommended to use a value that best defines the station under test from other stations.
Use the up and down arrows on the keypad to insert characters. Use the right arrow to move
the cursor for the next character.
If left blank the default SSID for the QPM Expert Alpha controller is QB-serialnumber, where
serialnumber is the serial number of the controller; i.e. QB-032014007.
Password
This parameter sets the encryption key needed to connect a wireless device to the access
point in the QPM Expert Alpha controller. Must be a minimum of 8 characters and no longer
than 63 printable characters or 64 hexadecimal digits.
Use the up and down arrows on the keypad to insert characters. Use the right arrow to move
the cursor for the next character.
This parameter can be left blank.
Region
Select from the drop-down list the region of the world where the tool is operating. This
selects the correct frequency channels allowed by that region.
2.5.3 Pair QPM Cordless Tool to QPM Expert Alpha Controller
NOTE: Do not remove the battery pack from the QPM cordless tool during this process.
Navigate to the WIFI tab under SETUP/ COMMUNICATIONS. Press the PAIR button. WAIT 45 SECONDS AFTER
PRESSING THE PAIR BUTTON BEFORE CONTINUING. This will put the QPM Expert Alpha controller into search
mode.
Bring the QPM cordless tool within range of the associated QPM Expert Alpha controller. Install the battery pack
into the tool. Press and hold the MFB then tap the start trigger switch at the same time. The tool will emit a
chirp indicating it is starting the pairing process. This may take up to 15 seconds. Release the MFB. The orange
PM light will flash slowly to indicate it is searching for the QPM Expert Alpha controller. When it connects the PM
light will extinguish. If the tool does not make a connection to the QPM Expert Alpha controller after 2 minutes
the QPM cordless tool will exit pairing mode and the process will need to be started again.
2.5.4 Add the QPM Cordless Tool as a Trailing Spindle
The QPM cordless tool’s status lights will flash in sequence indicating it is requesting to be added as a trailing
spindle on the QPM Expert Alpha controller.
Select the desired number for the trailing spindle and press the OK button.
The tool will attach itself as a trailing spindle of the QPM Expert Alpha controller. Press the BACK button. The
tool will briefly disconnect from the QPM Expert Alpha controller and then reconnect. Do not remove the battery
pack during this process.
Select the spindle tab which corresponds to the QPM cordless tool recently connected and program it to run the
desired fastening strategy.
2.6 Tool Installation
Connect the STANLEY QPM cordless tools to a QPM Expert Alpha controller and program it for the operation
!
Summary of Contents for QPM CORDLESS TOOL
Page 5: ...Instruction Manual V Table of Contents 5 9 Return Material Authorization RMA Procedures 49...
Page 6: ......
Page 23: ...Instruction Manual 17 Introduction...
Page 24: ......
Page 38: ......
Page 48: ......
Page 49: ...Cordless Tools 4 Preventive Maintenance Calibration Repairs Cleaning Disposal Maintenance...
Page 52: ......