Page 139
CPV550
25.0.2 Cartridges
To check the C-CARD and its connector.
Internal Data Base Test
To test the WorldWideBackground.
C-CARD Test
To test the C-CARD. There are the possible situations:
1. if there is a C-CARD inserted in the slot and there is not a malfunction, the name of the
C-CARD zone and the message "OK" are shown.
2. if there is a C-CARD inserted in the slot, but it is a defective C-CARD, the name of the
C-CARD zone and the message "Faulty" are shown.
3. if there is not any C-CARD inserted in the slot, the message "not present" is shown.
4. if there is a User C-CARD inserted in the slot, the message
USER C-CARD
is shown.
C-CARD Connector
Indicates if there is a malfunction in the connector.
25.0.3 Serial Ports
If you are having problems receiving data from the position-finding instrument, this test
should help determine the problem.
Change Parameters
To change the parameters of the serial interface. This menu allows to select the
Port
(Signal
Source) between PORT 1, PORT 2, PORT 3, PORT4; the
Baud Rate
between 300, 1200,
2400, 4800, 9600, 38400, 115200; the
Data Bits
(Word Length) between 7 or 8, the
Parity
between even, odd or none, the
Stop Bits
between 1 or 2. Default settings are: Port = PORT
2, Baud Rate = 4800, Data Bits = 8, Parity = none, Stop Bits = 1.
Input Data Display
To allow the GPS chartplotter to act as a computer terminal and display the incoming data
exactly as it is received. If the data displayed on the screen is unrecognizable, you may have
selected the wrong input parameters for your particular receiver, for example, Baud Rate
9600 instead of Baud Rate 4800. Check your receiver manual to be sure that you have
selected the proper parameter. If the screen is blank, you may have a broken connection,
and no data is being received or you may have connected the device to the other input port.
Use
[ZOOM]
to stop (or continue after pause) data displaying,
[ENT]
to show data in hex
or ASCII mode (normal or small) and
[CLR]
to exit.
Loop-Back Test
This is a special test done during the production phase to check the serial ports integrity.
A special connector is required.
25.0.4 Modem test
Checks the Modem connections (to be used only if the C-COM Modem is connected).
Press
[ENT]
to select the desired Modem Port to the Port to which the Modem C-COM is
connected.