General technical data
11.1 Power
circuit
galvanic separation from control circuit
in acc. with EN 50178 / VDE 0160
specification in accordance with
UL 508C and cUL
short circuit and to frame proof for
Min. 2000 releasings
overvoltage monitoring D6R..-3
Max. 400V DC
±
5V DC
overvoltage monitoring D6R..-7
Max. 765V DC
±
10V DC
undervoltage monitoring
min. 15V DC; configurable
overtemperature switch off at
95 ° C +/- 5%
clock frequency
4,75 kHz
frequency of current ripple
9,5 kHz
11.2 Control
circuit
galvanic separation from power circuit
in acc. with EN 50178 / VDE 0160
further information:
see concept of insulation chapter 1.3.1
see data compact units chapter. 1.3.3
see data plug-in modules chapter 1.3.4
11.3 Signal inputs and outputs, connection X10
additional galvanic separation from power and
control circuit
nominal voltage of the in- and outputs
24 V DC
number of outputs
signal outputs via OPTO coupler
5
Umax = 45V DC;
I = 0..60 mA; short circuit proof, resistive load
signal outputs via RELAY
Umax = 45V DC;
I = 1uA...1,2A
contact protection with inductive load
internal varistor
number of inputs
signal outputs via OPTO coupler
8
L = 0...7 V DC or open
H = 15...30 V DC
Iin 24VDC: 8 mA
Shortest time of signal at all input to accept the
signal in an application:
> 1 ms
Damping of the transfer from
low to high (0-->24V):
fast input:
20µs (X10.4, X10.25)
default input:
200µs
Interrupt response time for fast input
10µs (X10.4, X10.25)
Damping of the transfer from
high to low (24-->0V)
fast input:
250µs (X10.4, X10.25)
default input:
1000µs