Product Manual Type:
637f
07-02-10-01-E-V0304.doc
Pin assignment and functions
2.7
Option module RP SBT
2.7.1 Safe
Stop
Connector assignment X290:
Pin
Designation
Note
Status
1 Input
Active
1)
OPTO Input
2
Reference point Input Active
OPTO
Input
3
Starting lockout deactivated
Relais
Input
4
Reference point Starting
lockout
Relais
Input
5
Checkback contact
Free contact
Break contact
6 Checkback
contact
Free contact
Break contact
Hinweis:
1)
With employment the option module RP SBT changes the function “AKTIV” from the connecting
plug X10.22 after X290.1! The input X10.22 can be used then as free programmable input (BIAS).
Use of the function
Safe Stop
The option RP_SBT of the drive controller 637fxx-x.S5 supports the safety function “Safe Stop”, protection
against unexpected starting, according to the requirements of the EN954-1 “Category 3” and EN1037.
The stop of the machine must be caused and guaranteed before by the external machine control.
This applies in particular to vertical axes without selflocking mechanics or counterweight.
If an error arises in the drive system during the active brake phase, the axis can coast down uncontrolled or
even accelerate actively.
In order to use the Starting lockout function intended, it is to be looped into the net contactor circle or
emergency stop circle with the obligation-led reporting contact X290.5/6. With not plausible functioning of the
Starting lockout relay, related to the operating mode of the machine, a galvanic separation of the drive
concerned from the net must take place. The Starting lockout and the associated mode may be used again
only after error correction.
Due to a danger analysis / view of risk (to be accomplished according to machine guideline 89/392/EWG
and/or EN 292; EN 954 and EN 1050) the machine manufacturer must project the safety circuit of its
machine types for the
entire machine
including all integrated components (also the electric drives).
Block diagram: