77
2080
3010
2500
fixing set screws
X
G1/4
G1/4
DRAIN
NPT1/8
black jig
(assembly tool)
2080
3010
2500
fixing set screws
X
STEAM
PLUG
CONDENSE LINE
NPT1/8
G1/4
A.0500.351 – IM-TGH/07.02 EN (10/2015)
TN3 cartridge used with steam quench
If the TN3 cartridge is used with steam quench connect steam and condense line according to fig
TN3 Steam.
Fig TN3 – View on arrow X
• Remove black jig (1x) before fixation of shaft sleeve
(allows shaft sleeve to rotate).
• Remove non-coloured jigs (3x) after pump assembly
and adjusting axial clearance.
Fig TN3 Steam – View on arrow X
• Remove black jig (1x) before fixation of shaft sleeve
(allows shaft sleeve to rotate).
• Remove non-coloured jigs (3x) after pump assembly
and adjusting axial clearance.
1. The steam can been connected to one G1/4 opening at the left or the right side of the bracket.
The opposite G1/4 opening must be plugged off.
2. A condense line can been connected to the NPT 1/8 opening if any; otherwise allow this
NPT 1/8 opening to open so allowing steam to expel into the atmosphere.
Steam pressure must be released in such a way that only a small stream of steam is expelled into
to the atmosphere.
3. Take the necessary safety precautions to prevent injuries by steam during operation and
maintenance.