• Benaming
/
Description
:
Nameplate 86x54 - Pump Unit
• Artikelnummer
/
Article number
:
4.0030.170
• Afgeronde hoeken
/
Rounded edges
: R4mm
•
Ø
gaten
/
Ø holes
: 2mm
• Afmeting SPX-logo
/
Dimensions SPX-logo
: 32mm x 8,63mm
• Tekst firmagegevens /
Text company data
:
lettertype
/
font
:
Arial regular
lettergrootte
/
fontsize
: 7pt
• Afmeting JP-logo
/
Dimensions JP-logo
:
45mm x 5,2mm
A.0500.351 – IM-TGH/07.02 EN (10/2015)
1.3.2.3 Before commissioning the pump unit
Read the pump’s operating and safety manual. Make sure that the installation has been correctly
carried out according to the relevant pump’s manual.
Check the alignment of the pump and motor shafts. The alignment may have been altered during
transport, lifting and mounting of the pump unit. For safe disassembly of the coupling guard see
below: Disassembly/assembly of the coupling guard.
Warning
The pump unit must not be used with other liquids than those for which it was recommended and
sold. If there are any uncertainties contact your sales representative. Liquids, for which the pump is
not appropriate, can damage the pump and other parts of the unit as well as cause personal injury.
1.3.2.4 Disassembly/assembly of the coupling guard
The coupling guard is a fixed guard to protect the users and operator from fastening and injuring
themselves on the rotating shaft/shaft coupling. The pump unit is supplied with factory mounted
guards with certified maximum gaps in accordance with standard DIN EN ISO 13857.
Warning
The coupling guard must never be removed during operation. The locking safety switch must be
turned to off and locked. The coupling guard must always be reassembled after it has been removed.
Make sure to also reassemble any extra protective covers. There is a risk of personal injury if the
coupling guard is incorrectly mounted.
a) Turn off and lock the power switch.
b) Disassemble the coupling guard.
c) Complete the work.
d) Reassemble the coupling guard and any other protective covers. Make sure that the screws are
properly tightened.
1.3.2.5 Name plate – CE Declaration of Conformity
Always quote the serial number on the name plate together with questions concerning the pump unit,
installation, maintenance etc.
When changing the operating conditions of the pump please contact your supplier to ensure a safe
and reliable working pump.
This also applies to modifications on a larger scale, such as a change of motor or pump on an
existing pump unit.
Summary of Contents for TG H15-50
Page 103: ...103 A 0500 351 IM TGH 07 00 EN 10 2015...
Page 105: ...105 A 0500 351 IM TGH 07 00 EN 10 2015...
Page 106: ...106 A 0500 351 IM TGH 07 00 EN 10 2015...
Page 107: ...107 A 0500 351 IM TGH 07 00 EN 10 2015...
Page 108: ...108 A 0500 351 IM TGH 07 00 EN 10 2015...
Page 109: ......