background image

 

Enviro Maintenance Manual 2004 

LV10 PANEL

LOCATED ON

KES FILTER

____ HP 

EXHAUST FAN MOTOR

THREE WIRES FROM LV10 PANEL TO EXHAUST FAN MOTOR STARTER BY

MECHANICAL WHEN KES FAN AND FILTER SECTIONS ARE SPLIT  120V/1/60, 5 AMPS

TEN (10) WIRES TO THE 

RPW10 - 120V/1/60 - 10 AMPS.

TO REMOTE CONTROL STATION LOCATED IN

IN THE KITCHEN AREA MODEL RPD10 OR

1&4

15

18

16
17

12

14

13

5

14

TERMINAL

18

16

17

15

5

13

12

1

4

POWER FROM RPD10

KES FAN/NORMAL OPERATION

BAG FILTER CLOGGED

FIRESTAT - HIGH LIMIT
0DOR SPRAY UNIT

FILTER OUT/LOW AIR

BOX FILTER CLOGGED

PREFILTER CLOGGED

LV10 RESET

DESCRIPTION

LEGEND

RESET

1

UNIT

ENCLOSURE

TRANSFORMER

DISCONNECT

30 AMP

EEMAC3R

T2

L2

T 2

L2

T3

M1

WIRING HARNESS IN

MOTOR STARTER

120V

XXXV

L3

7

1 3

6

95

G1

96

T 3

A2

L3

A 1

T1

KES TELE MOTOR STARTER

IN EEMAC4 ENCLOSURE

MOUNTED ON FAN UNIT

L1

EEMAC4

M1

T 1

O/L

L1

FILTER REMOVED SWITCHES

EXHAUST INLET SET AT 225 °F

HI TEMP STAT LOCATED IN THE

P5 - BOX FILTERS (SET AT 0.25" W.C.)

P4 - BAG FILTERS (SET AT 0.25" W.C.)

TH1

P5

P4

FILTER CLOGGED PRESSURE SWITCHES

P2 - BAG FILTER (SET AT 1.0" W.C.)

P1 - PREFILTER (SET AT 1.0" W.C.)

P3 - BOX FILTER (SET AT 1.2" W.C.)

P2

P3

P1

17

TO THE ODOUR CONTROL UNIT 120V/1/60

4.2 AMPS. MAXIMUM. WIRES BY SPRING AIR

WIRING FROM EXHAUST FAN MOTOR STARTER

4

LOCATED ON KES FAN SECTION

OPTIONAL ODOUR CONTROL PANEL

TO FACTORY MOUNTED BASEBOARD HEATER

WITH THERMOSTAT FOR SPRAY ENCLOSURE

____ FLA

POWER SUPPLY

____V/3/60

CONTROL WIRING BY MECHANICAL CONTACTOR
FACTORY WIRING BY SPRING AIR SYSTEMS

POWER WIRING BY GENERAL CONTRACTOR

KESF FAN SECTION

KES-ISH FILTER SECTION

Wiring diagram for Outdoor KES, motor starter, LV10 J-Box, and odor unit 

Figure 21 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for KES Enviro

Page 1: ...KES Enviro Maintenance Manual ___________________________ Spring Air Systems Inc Oakville Ontario Phone 905 338 2999 Fax 905 338 0179 info springairsystems com...

Page 2: ......

Page 3: ...or AP MP Panels 4 Filter Hood or Dry Grease Extractor 5 Control Circuit 7 Setting the Day and Time 13 Setting the Weekday Fan ON and OFF Times 14 Setting Weekend Operation 15 Odor Spray Systems 15 Whe...

Page 4: ......

Page 5: ...ries Inc UL listing allows the kitchen exhaust air to be discharge to atmosphere at low levels Prior to any installation the installer must seek approval from the authorities having jurisdiction THE S...

Page 6: ...L E C T R I A L W I R I N G A N D N A T I O N A L C O D E R E Q U I R E M E N T S S H A L L C O N F O R M T O A L L L O C A L N O T E 1 I N T E R N A L W I R I N G B Y S P R I N G A I R C U R C U I T...

Page 7: ...S TO THE WET CHEMICAL SWITCH 120V 1 60 1 AMP MOTORIZED INLET DAMPER AND END OPTIONAL THREE 3 WIRES TO OPTIONAL POWER SUPPLY TO SUPPLY FAN MOTOR STARTER 120V 1 60 2 AMPS DRY CONTACT FOR BUILDING FIRE A...

Page 8: ...ses and sends power through terminals 3 4 to the RPW10 remote panel to energize the exhaust fan through terminals 5 4 in the LV 10 J Box The LV10 J Box is mounted on the KES ISH filter section The NOR...

Page 9: ...1 2 ESC OK 1 Q 3 1 Q 1 1 2 Q4 1 2 Q2 15 AMP CURCUIT BREAKER AUX FAN SWITCH I4 I2 L N I1 I3 01 20 03 Mo 09 00 I 5 I 6 I7 I8 L N OVERIDE SWITCH OFF ON RPD10A ELECTRICAL DATA I 1 I 2 I 3 I 4 RUN STOP BOX...

Page 10: ...Internal Wiring Figure 10 REMOVED WARNING CLOGGED BOX FILTER FILTER OVERIDE BAG FILTER CLOGGED PREFILTER CLOGGED NORMAL FIRE IN PANEL BACK HOLES LOCATED PANEL MOUNTING KES OFF ON FILTER 8 0 14 0 5 RPD...

Page 11: ...C P4 BAG FILTER REMOVED SWITCH COPPER TUBING REMOVED SWITCH SECTION TO RIGHT OF BOX FILTER ACCESS DOOR PRESSURE SWITCHES LOCATED ON KES ISH FILTER BOX P5 B A G P4 P 3 P2 PREFILTER P 1 Pressure Switch...

Page 12: ...P4 BAGFILTERS SETAT0 25 W C L1 O L L2 L3 T1 T3 T2 A1 A2 6 3 7 M1 WIRINGHARNESSIN MOTOR STARTER THREE WIRES FROM LV10 PANEL TO EXHAUST FAN MOTOR STARTER BY MECHANICAL WHEN KES FAN AND FILTER SECTIONS A...

Page 13: ...he KES unit or within the KES unit a firestat located at the inlet of the KES filter section is activated When the exhaust air reaches 160 F the firestat is energized The exhaust fan shuts off the NOR...

Page 14: ...osition Figure 17 System Reset After any of the safety circuit annunciation the system must be reset The system is reset by toggling the RESET switch in the LV10 J box or switching the OVERRIDE SWITCH...

Page 15: ...Enviro Maintenance Manual 2004 RPD10 Face Plate Figure 19 RPW10 Face Plate Figure 20...

Page 16: ...3 7 1 3 6 95 G1 96 T 3 A2 L3 A1 T1 KES TELE MOTOR STARTER INEEMAC4ENCLOSURE MOUNTED ON FAN UNIT L1 EEMAC4 M1 T 1 O L L1 FILTER REMOVED SWITCHES EXHAUSTINLETSETAT225 F HI TEMP STAT LOCATED IN THE P5 BO...

Page 17: ...01 00 Th 00 00 Su 06 16 01 01 00 MM DD YY Set Clock Set Clock MM DD YY 01 01 00 Th 00 00 Set Clock Su 00 00 01 01 00 MM DD YY Prg Name Set Clock Set Parma Set Clock Set Parma Prg Name Stop to return...

Page 18: ...Press to remove Monday from the weekly schedule The dash indicates The cursor will move to M Monday 5 The clock has been factory set to turn the fan on at 6 00 a m and off 8 Press to move to the next...

Page 19: ...ess If your selection is complete press and to return the 9 Press operating screen 10 You have completed programming weekend fan On and Off cycling 01 06 03 Su 06 16 B04 No2 On 10 00 D SS B04 No2 Off...

Page 20: ...g the setting by is not adequate decrease the cycle to of the original setting If this is not adequate adjust the spray timer B02 a Increase the spray time B02 in increments of 5 seconds After each 5...

Page 21: ...s are minutes and the two digits to the right are seconds Press to change the cycle length in minutes Press to move to the T 05 00m 9 To change spray time press 11 Press if the cycle time is correct 8...

Page 22: ...tlet valves are interchangeable Clean them with water When replacing the outlet valve place the new valve in location and note there is a retaining bar near the machine screw hole This retaining bar h...

Page 23: ...x 24 x 22 V9 4M Class II American Air Filter 24 x 24 x 21 DRI PAK Class II 12 x 24 x 21 DRI PAK Class II Farr Filters 24 x 24 x 22 90 ASHRAE 52 76 Class II 12 x 24 x 22 90 ASHRAE 52 76 Class II BOX F...

Page 24: ...oved pressure switch The switch must make and close after 30 seconds of operation Adjust the pressure setting or replace switch i If all the filters are in place check if pressure tips on the end of t...

Page 25: ...pen Replace if necessary V Fire Pilot On 1 The fire stat in the KES filter section exhaust outlet has activated and shut the KES system down If a fire is not present check calibration of firestat TH1...

Page 26: ...system For heavy cooking applications the bag filters may require replacement every month 4 Odor Spray Option Inspect the odor spray bottle Refill if necessary At startup the odor spray is adjusted t...

Page 27: ...years of service under most conditions 2 Re greasing of motors depends on the application and is best left to trained service technicians 3 Periodically check if motor is running hotter then normal C...

Page 28: ...Turn on the Override switch in the RPD10 or RPW10 remote panel The LOGO text message Service Filters within 4 hours will appear Turn FAN OFF switch in the wash panel or remote RPD10 panel to the OFF p...

Page 29: ...sted With the filters out rotate the pressure adjustment screw slowly clock wise until the unit shuts off Fire Switch Test 41 Jumper terminals 1 16 in the LV10 J Box 42 KES unit shuts off Yes No 43 Fi...

Page 30: ...nance Manual 2004 FILTER FREQUENCY CHART Enter the date of each filter change Startup date Change No Prefilter Bag Filter Box Filter Odor 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24...

Page 31: ...ater Wash Cold Water Spray Hot Water Wash Water Wash Control Panels Dry Ventilators REV LOW Hood Filter Hoods Surface Fire Suppression Commercial Kitchen Exhaust Fans Kitchen Enviro Systems KES 100 Ex...

Reviews: