4. Installation
Danger!
All tasks on the device are only allowed to be undertaken by specialist personnel taking
into account the relevant safety regulations. Always pay attention to the safety instruc-
4.1. Mechanical
installation
Danger!
Transport the control stand using suitable hoisting equipment.
Attention!
Cables are routed from below.
During installation, make sure that the cables are not trapped or kinked.
Variant with mounting base
Figure 13.
8
13
13
13
13
240
16
R8
240
29
Mechanical installation – mounting base – example (dimensions in mm)
1. Position the control stand in the installation location, during this process pay attention to the cor-
rect minimum distance to neighboring parts. The rotating and swiveling area of the control stand
must not be blocked.
2. Fasten the control stand in the installation location using 4 suitable screws M8 through the fasten-
ing holes (
13
) in the mounting base (
8
) (tightening torque 72 Nm).