![Spirent DLS 400E3 Operating Manual Download Page 60](http://html1.mh-extra.com/html/spirent/dls-400e3/dls-400e3_operating-manual_1348156060.webp)
DLS 400E3 Operating Manual
Page 11-2 - Spirent Communications
7104000537 03/04 -2
•
2 fuses
Options
•
National Instruments IEEE 488 card (for the controlling PC)
•
DLS 5200E3 Custom Noise Generator (external)
•
DLS 5103 External Noise Generator
•
1 or 2 DLS 5A01H Noise Impairment Generation Module(s) for injection of differential noise on one or
both sides of wireline
•
DLS 5402DC Differential or Common Mode Noise Injection
•
DLS 1310-E3 Compensation (automated software)
•
SmartBits SMB 200/2000 Traffic Genearation and Analysis
Electrical (AC Power)
Rated Input Voltage:
100-240 VAC (±10%) with automatic line voltage sensing
Rated Frequency:
50-60 Hz
Rated Power consumption:
120 VA max.
Line Fuses:
Type "T" 2A/250V SLOW BLOW (2 required, 5 mm x 20 mm)
Environmental
Operating Temperature:
+10°C to +40°C (50°F to 104°F)
Storage Temperature:
+10°C to +40°C (50°F to 104°F)
Humidity:
90% (non-condensing) max.
Mechanical:
Weight:
28 kg (61 lbs) per chassis
Dimensions:
194 mm x 452 mm x 494 mm
(7.6" x 17.8" x 19.4")
(H x W x D)
11.2 Operating Conditions
In order for the unit to operate correctly and safely, it must be adequately ventilated. The DLS 400IA Series
contains ventilation holes for cooling. Do not install the equipment in any location where the ventilation is
blocked. For optimum performance, the equipment must be operated in a location that provides at least 10
mm of clearance from the ventilation holes. Blocking the air circulation around the equipment may cause the
equipment to overheat, compromising its reliability.
Summary of Contents for DLS 400E3
Page 1: ...Operating Manual DLS 400E3 ADSL European Wireline Simulator Revision 2 March 2004...
Page 2: ......
Page 10: ...DLS 400E3 Operating Manual Page 1 6 Spirent Communications 7104000537 03 04 2...
Page 52: ...DLS 400E3 Operating Manual Page 7 2 Spirent Communications 7104000537 03 04 2...
Page 56: ...DLS 400E3 Operating Manual Page 9 2 Spirent Communications 7104000537 03 04 2...
Page 58: ...DLS 400E3 Operating Manual Page 10 2 Spirent Communications 7104000537 03 04 2...
Page 64: ...DLS 400E3 Operating Manual Page 12 4 Spirent Communications 7104000537 03 04 2...