DBW 160/230/300/350
Technical data
87
Heizgerät
DBW 160
DBW 230
DBW 300
DBW 350
ECE type approval number acc. to R10 (EMC)
035038
ECE type approval number acc. to R122 (Heater)
000204
000205
000206
000207
Kind of construction
High pressure atomiser
Heating flow
kW
(kcal/h)
16
(13 800)
23,3
(20 000)
30
(26 000)
35
(30 000)
Fuel
Diesel acc. DIN 51601
Fuel consumption
kg/h
1,9
2,5
3,3
3,7
Rated voltage
V –
12 or 24
24
Operating voltage range
V –
10...14 / 21...28
21...28
Rated power consumption
(without circulating pump)
W
100 (12V)
90 (24V)
110 (12V)
110 (24V)
100 (12V)
130 (24V)
.62: 100 (24V)
170 (24V)
Max. ambient temperature during operation
(Heater, control module, circulating pump)
°C
-40... + 60
Max. storage temperature
(Heater, control module, circulating pump)
°C
-40... + 85
Max. operating overpressure
bar
0,4...2,0
Capacity of the heat exchanger
l
1,1
2,4
Minimum capacity of the system
l
10,00 I
CO
2
in exhaust gas at rated voltage
Vol %
10,5
±
0,5
CO in exhaust gas
Vol %
0,2 max.
Smoke number (Bacharach)
Vol %
< 4,0
Heater dimensions (Tolerance
±
3 mm)
mm
mm
mm
Length 584
Width 205
Height 228
Length 681 up to .32
Length 680 up to .50
Width 230 up to .32
Width 240 up to .50
Height 279 up to .32
Height 269 up to .50
Length 681 up to .15
Length 680 up to .30
Width 230 up to .15
Width 240 up to .30
Height 279 up to .15
Height 269 up to .30
Length 725
Width 240
Height 279 up to .10
Height 269 from .11
Gewicht
kg
14,5
24 from .33: 22
24 from .33: 22
23
Electrical components:
Control module, motors for combustion air fan and circulating pump, solenoid valves, electronic ignition unit and digital timer are rated at either 12 or 24 volts. The com-
ponents overheat fuse, thermostats, temperature limiter, flame sensor and switches are independent on voltage.