background image

6.1 DOWNLOAD THE APPLICATION

Figure 7

1.  Using either App Store

®

 for Apple

®

 or Google Play™ store  

for Android™ platforms, search for “Sperry Smart Meter” (Figure 7) 
and select “GET” for Apple

®

 or “Install” for Android™.

2.  Once the application has finished installing the  

SperrySmartMeter app icon will appear on your device.

6.2 OPENING THE APPLICATION

1. Locate the Sperry SMARTmeter app.
2. Touch the icon to open.

6.3. CONNECTING YOUR SMART DEVICE

 

After the opening the 

app, select DM6850T

1

Press the blue flashing 

“CONN” button on 

the app, follow the 

on-screen directions.

3

It may be necessary 

to press “scan” on 

your phone/tablet to 

complete step 4.

4

9

To toggle the meter 

selected when already  

in the app, tap the  

blue bar at the top

2

Summary of Contents for DM6850T

Page 1: ...on and off and select the desired measurement function To save battery power turn to the OFF position when the meter is not in use See ROTARY SWITCH section for function descriptions 8 MAX MIN Button...

Page 2: ...safe condition Read through and understand the instructions contained in this manual before using the instrument Keep the manual at hand to enable quick reference whenever necessary The instrument is...

Page 3: ...the meter in areas where vibration dust or dirt is present Do not store the meter in excessively hot humid or damp places This meter is a sensitive measuring device and should be treated with the sam...

Page 4: ...0V 0 01V 400V 0 1V 600V 1V 1 2 8 Main Display Average Current Input Impedance 10M Frequency Response 50Hz 400Hz AC VOLTAGE RANGE RESOLUTION ACCURACY 0 1 30 Buzzer beep 30 100 Buzzer may or may not bee...

Page 5: ...least 2 seconds to turn off Bluetooth communication The symbol will be absent from the display 4 6 RELATIVE MEASUREMENT 1 The meter has a relative measurement feature that will display measured value...

Page 6: ...ean value response When the measured current is 5 amps continuous measurement is acceptable When the measured current is 5 10 amps do not exceed 10 seconds of continuous measurement Wait 15 minutes be...

Page 7: ...ut is not connected i e at open circuit OL will be displayed as an overrange indication Diode 1 Insert the black negative test lead into the COM input terminal 2 Insert the red positive test lead into...

Page 8: ...leads 2 Rotate the dial to the NCV position 3 The meter will display EF when the NCV function is being used Figure 3 4 Move the top of the meter close to the object to be tested 5 When the meter dete...

Page 9: ...errySmartMeter app icon will appear on your device 6 2 OPENING THE APPLICATION 1 Locate the Sperry SMARTmeter app 2 Touch the icon to open 6 3 CONNECTING YOUR SMART DEVICE After the opening the app se...

Page 10: ...OK button is pressed your smart device will begin recording data points As it is doing this you will immediately be prompted to name the file or accept the default file name 6 Data points will contin...

Page 11: ...the data was previously saved it can be reopened 6 6 3 Deleting saved files 1 To delete saved files press the File button 2 Press Open on the screen that appears 3 A list of saved files will be displa...

Page 12: ...change the name enter the new name and press Save iOS only 5 If you wish to continue sharing with the default or previously assigned name just press Save iOS only 6 You will be given the option to sh...

Page 13: ...to possible electric shock or personal injury replace the battery as soon as the battery indicator 1 8 8 8 Autorange MAX MIN AC DC appears 1 Disconnect the connection between the test leads and the ci...

Page 14: ...uch products shall not have been altered by the distributor The distributor shall be fully responsible for any warranties the distributor makes to its purchasers which are broader or more extensive th...

Reviews: