DC Volts
To avoid personal injury or damage to the Meter, do not attempt to measure voltages higher than 600 VDC.
1. Insert the black (negative) test lead into the
COM input terminal.
2. Insert the red (positive) test lead into the
INPUT terminal to the right of the COM terminal.
3. Set the Rotary Switch to
A
A
400A
400A
4. Press the “
SELECT” button until DC is shown on the display.
5. Touch the test leads to the circuit under test. Touch the black (common) test lead to the
negative DC source (ground) first and red (positive) test lead to the “live” source second.
6. Read the value of the measurement displayed. If the leads are reversed a
“-“ indicator will appear on the display.
7. Typical DC Voltage measurements include car batteries, automotive switches, motors, and household batteries.
5.2 AC/DC CURRENT
AC Amps
If the fuse burns out during measurement, the meter may be damaged or personal injury may occur. To avoid possible damage
to the meter or to the equipment under test, check the meter’s fuses before measuring current. Use the proper terminals, function,
and range for the measurement. Never place the test leads in parallel with any circuit or component when the leads are plugged
into the current terminals. Do not attempt to measure current exceeding 10A AC. If you are not sure if the current exceeds 10A
do not attempt to measure current with this meter.
1. Insert the black (negative) test lead into the
COM input terminal.
2. Insert the red (positive) test lead into the 10A terminal to the left of the
COM terminal.
3. Set the Rotary Switch to
A
A
400A
400A
.
4. Press the “
SELECT” button until AC is shown on the display.
5. Turn off power to the circuit to be measured.
6. Open the circuit to be measured.
7. Touch the red test lead to one side of the break in the circuit and the black test lead to the other side of the break in the circuit.
For AC Amp measurements the polarity of the leads does not matter.
8. Return power to the circuit.
9. Read the amps on the display.
Note: When measuring AC Amps this meter displays the effective value of the sine wave (mean value response).
When the measured current is <5 amps continuous measurement is acceptable.
When the measured current is 5–10 amps do not exceed 10 seconds of continuous measurement. Wait 15 minutes before performing
additional current measurements. Always turn off power to circuit and remove the leads from the circuit before removing and reinserting
the leads into the meter’s input terminals. Once the measurement is complete, immediately remove the test leads from the circuit under
test and remove the test leads from the input terminals of the meter.
DC Amps
If the fuse burns out during measurement, the meter may be damaged or personal injury may occur. To avoid possible damage to the
meter or to the equipment under test, check the meter’s fuses before measuring current. Use the proper terminals, function, and range
for the measurement. Never place the test leads in parallel with any circuit or component when the leads are plugged into the current
terminals. Do not attempt to measure current exceeding 10Amps DC. If you are not sure if the current exceeds 10Amps do not attempt to
measure current with this meter.
1. Insert the black test (negative) lead into the
COM input terminal.
2. Insert the red (positive) test lead into the 10A terminal to the left of the
COM terminal.
3. Set the Rotary Switch to
A
A
400A
400A
.
4. Press the “
SELECT” button until DC is shown on the display.
5. Turn off power to the circuit to be measured.
6. Open the circuit to be measured.
7. Touch the red test lead to the positive side of the break in the circuit and the black test lead
to the negative side of the break in the circuit for DC Amp measurement.
8. Return power to the circuit.
9. Read the amps on the display.
Note: When the measured current is <5 amps continuous measurement is acceptable. When the measured current is 5–10 amps
do not exceed 10 seconds of continuous measurement. Wait 15 minutes before performing additional current measurements.
Always turn of power to circuit and remove the leads from the circuit before removing and reinserting the leads into the meter’s
input terminals. Once the measurement is complete, immediately remove the test leads from the circuit under test and remove the
test leads from the input terminals of the meter.
6