34
CL & PSL50 Series
TROUBLESHOOTING
Error Code on Display
Potential Cause
Recommended Solution
EAB_2
Dispenser arm jammed during movement
Check movement
EDC_01...15
Motor running time exceeded. Container fails to achieve set
dosage (in gr).
Recalibrate container
EDB_01...15
Motor current exceeding the limit value. Req.EMK-pnts
could not be reached in max. allowed time.
Check container opening
Replace product
EDF_01...15
Motor has jammed 3 times (sluggish)
Check mixer
Perform run test
EE_08
Brewer-1 movement error
Replace brewer and/or drive
Close door correctly
EE_13
Brewer motor-2 not present
Check electrical connections
Replace brewer drive
EE_18
Brewer-2 movement error
Replace brewer and/or drive
Close door correctly
EEA_01
Error while closing, sieve head blocked
Check brewer movement.
Rinse toothed wheels of brewer
Check brewer assembly
Close door correctly
EEA_02
Exact closed position not reached
Check sieve head & filter
Clean sieve head and brewer
Error codes, causes, solutions
Summary of Contents for CL Series
Page 1: ...SpenglerTT_SM_EN Part No 10037114_03 CL PSL50 SERIES SERVICE MANUAL ...
Page 36: ...36 CL PSL50 Series Hydraulic diagram PSL50 ES12B SCHEMATICS ...
Page 37: ...37 CL PSL50 Series Hydraulic diagram PSL50 ES13 SCHEMATICS ...
Page 38: ...38 CL PSL50 Series Hydraulic diagram PSL50 FBT14 SCHEMATICS ...
Page 39: ...39 CL PSL50 Series Hydraulic diagram CL22 SCHEMATICS ...
Page 40: ...40 CL PSL50 Series Electrical diagram PSL50 series SCHEMATICS ...
Page 41: ...41 CL PSL50 Series Electrical diagram PSL50 series continued SCHEMATICS ...
Page 42: ...42 CL PSL50 Series Electrical diagram PSL50 series continued SCHEMATICS ...
Page 43: ...43 CL PSL50 Series Electrical diagram CL series SCHEMATICS Matchline ...
Page 44: ...44 CL PSL50 Series Electrical diagram CL series continued SCHEMATICS Matchline ...
Page 45: ...www creminternational com ...