The Ventura Remote Manual has one external port which is
reserved for the customer to set up a local display if
desired. The recommended display cable is a standard Cat
5e ethernet cable.
Electrical
-
Cont.
Wire Size Guide for the Ventura 12V:
Protect with 15 Amp Fuse or Circuit Breaker
10 Gauge (5mm²) up to 15 feet (4.5M)
8 Gauge (8mm²) up to 25 feet (7.5M)
6 Gauge (13mm²) up to 35 feet (10.6M)
Note
: If the specified circuit breaker sizes are unavailable, use the next higher rating
but do not exceed the specification by more then 10%. All wiring to be done to
applicable ABYC, Marine UL, or CE standards.
Distances at left represent the total
ROUND TRIP wire length (DC positive
length plus DC negative length), NOT
the length of the pair of wires
together. Size cables accordingly.
Mount the main power terminal block in a junction box or on a bulkhead
adjacent to the feed pump module. Make sure that this is a dry location
well above bilge level and not subject to water spray.
Be sure to install
the terminal block cover.
Check the wire size chart for appropriate wire sizes. DC power feeds should be uninterruptible
to ensure proper operation. Avoid house breaker panels that could be accidentally tripped.
Optional Z
-
Ion power and signal
cable (3
-
conductor, Green)
Fresh water flush solenoid
cable (2
-
conductor, Blue)
Do not apply voltage to the unit that exceeds 14.6 VDC. Serious damage to
the electrical system may occur.
WARNING
!
Summary of Contents for VENTURA 150
Page 2: ...2...
Page 4: ...4...
Page 6: ...6...
Page 13: ...13 Installation Notes...
Page 15: ...15...
Page 16: ...16 John Guest Super Speedfit Fittings...
Page 26: ...26 Operation...
Page 27: ...27...
Page 54: ...54 Insert pdf here after conversion to pdf...
Page 56: ...56 Exploded Views Part Numbers...
Page 57: ...57...
Page 63: ...63 Parts HP CYL 3 4R...
Page 64: ...64 PL MTS 3 8X1 2B HP CYL SST HP CYL CCA SO HPP ECCB HP CYL EC HP CYL R HP CYL PT Parts...
Page 65: ...65...
Page 69: ...69...
Page 71: ...71...
Page 74: ...74...