42
Pump runs intermittently,
cycling on/off
•
Overpressure switch on ShurFlo
pump opening
•
Adjust or replace switch (see
page 58)
Feed pump runs constantly,
will not turn off
•
Turn off manual switch on control box
•
Manual switch in ON
position on control box
Display activates, but pump
will not run
•
Loose or broken pump wire
connection
•
Tanks are full (if equipped
with tank switch). If full, Run
& Stop LED should be lit.
•
Check wiring at terminal block
inside control box
•
Check tanks–
system cannot be
started if tanks are full.
System runs, no product water
delivered to water tanks
•
Disconnected or broken prod-
uct tubing
•
3
-
Way Valve Incorrectly set
•
Check product tubing
•
Check 3
-
Way Valve position
Feed pump runs with loud
noise
•
Intake blocked
•
Air in system
•
Check thru
-
hull valve
•
Check sea strainer for leaks
•
Check fresh water flush module
for leaks
•
Re
-
prime system (restart)
Troubleshooting Ventura Remote Manual Systems
SYMPTOMS
PROBABLE CAUSE
REMEDY
High feed pressure, High Am-
perage, & Product Flow down
up to 15%
•
Colder or more saline water
•
Brine or product flow path
subject to back pressure
•
Scaled or fouled membrane
•
Normal condition
•
Confirm by routing into a bucket to test
•
Clean Membrane
Feed Pump not running, no
noise
•
No power at feed
pump
•
Pressure switch Failed
•
Check voltage at pump
•
Adjust or bypass. To
bypass, jump terminals
on switch with electri-
cal wire. Only bypass
to test, not run long
term.
Feed pump turns on, no pres-
sure
•
Feed pump air locked
•
Pressure relief valve open
•
Open pressure relief valve
to bleed the air, then close
to start
•
Close pressure relief valve
Low Feed Pressure, Low Am-
perage
•
Warm saltwater or brackish
water
•
Normal condition
No product flow, good brine
discharge flow,
Recovery percentage is 0 (See
Flow Test)
•
Internal leak in Clark Pump
•
While system is running, kink brine
hose to stop flow until pressure rises
to 125psi, release hose quickly, repeat
no more than 10 times in succession
•
Inspect Clark Pump Check Valves
•
Complete Service is recommended.
Contact Dealer or see Clark Pump re-
build manual. Install Offshore Kit
Summary of Contents for VENTURA 150
Page 2: ...2...
Page 4: ...4...
Page 6: ...6...
Page 13: ...13 Installation Notes...
Page 15: ...15...
Page 16: ...16 John Guest Super Speedfit Fittings...
Page 26: ...26 Operation...
Page 27: ...27...
Page 54: ...54 Insert pdf here after conversion to pdf...
Page 56: ...56 Exploded Views Part Numbers...
Page 57: ...57...
Page 63: ...63 Parts HP CYL 3 4R...
Page 64: ...64 PL MTS 3 8X1 2B HP CYL SST HP CYL CCA SO HPP ECCB HP CYL EC HP CYL R HP CYL PT Parts...
Page 65: ...65...
Page 69: ...69...
Page 71: ...71...
Page 74: ...74...