Storage Procedure: SC
-
1 powdered preservative (good for 6 months):
1. Fill a bucket with 3 gallons of fresh unchlorinated water. Mix 2 containers of the SC
-
1 stor-
age chemical compound into the water in the bucket. Note that it will take about an hour for
all the chemical to dissolve.
2. Insure that the system has been flushed in the last 5 days or run the system until the flush
tank is full and do a fresh water flush..
3. Install the service hoses from the service kit on to the inlet and discharge connections front
of the unit and put the other end in the bucket with the SC
-
1 turn the yellow service valve to
service.
4.
Open the pressure
relief valve on the
high pressure one
full turn.
5. Close the flush tank valve (located under the flush tank)
Handle left is run/flush Right is drain Halfway is off
6. Flip the Service Speed toggle switch to
“
on
”
the control box to
“
Service
”
to turn on the pump
and circulate the storage chemical in the system for at least 20 minutes.
Flip the service speed switch to off.
Clean Up:
•
Remove the service hoses and replace the dust caps. Turn the the flush tank and run /
service valves back to the
‘
Run
’
position.
•
Remove the filter bowls, rinse with the storage solution and reinstall with clean dry filters.
This should be a clean operation so you do not introduce bacterial into the filter bowles.
•
Discard the remaining liquid in the bucket to a suitable drain.
•
Turn off the power to the system.
LEAVE THE PRESSURE RELIEF VALVE OPEN 1 FULL TURN AND LEAVE A NOTE ON
THE SYSTEM SHOWING THAT IT IS FULL OF STORAGE SOLUTION AND THE DATE.
ALSO MAKE A NOTE IN THE LOG BOOK.
Run/Service Valve
to service
Discharge/Service
Outlet
Feed/Service Inlet
Long Term Storage Procedures
Summary of Contents for LB-1800C
Page 2: ...2 Page Intentionally blank...
Page 4: ...4 Page Intentionally blank...
Page 33: ...33 Black Parker tube fittings...
Page 34: ...34 John Guest Super Speedfit Fittings...
Page 48: ...48...
Page 49: ...49...
Page 50: ...50...
Page 51: ...51...
Page 52: ...52...