32
GEARCASE LUBE OIL
Use only 5W
-
30 synthetic oil in Spectra
-
Pearson Pump crankcase. Do not overfill the
crankcase with oil. Check oil condition and level frequently. The oil should be
changed every 5000 hours of operation or annually, whichever comes first.
The Spectra–
Pearson Pump comes mounted on a CAT
™
crankcase.
Inspect the oil
level and condition often.
The oil in the crankcase should be changed every 5,000 hours or when the oil appears
milky. Note that if the oil appears milky it is time to change the seals as water is get-
ting into the crankcase from the pump head. There is an inspection window on the
back side of the crankcase that will show the oil level and condition.
Inspection
Window
Drain tube
Push in collar
on fitting and
pull out drain
tube
Route drain
tube so oil will
drain into an
appropriate
container
Vented Oil
Cap
1.
The oil will drain better if it is warm , after the system
has been running for a few hours.
2. Disconnect the drain Tube from the (push
-
to
-
connect)
fitting by pushing the collar in and pulling the tube out.
See instructions on pg.33
3. Replace drain tube and refill with 1 pint (450ml)
5W
-
30 Synthetic oil.
Please dispose of used oil responsibly.