39
LCD Brightness:
Set brightness of the hardwired display(s) from
10
—
100%
System Units:
Change from US Standard units to Metric
Factory Reset:
Resets any changed parameters a user has made back to the factory de-
faults for that configuration.
CAUTION!! Never disable a Fault Alarm without being certain that the issue is with a
bad sensor. Disabling a fault and running the system can cause serious damage or in-
jury.
High Pressure Fault:
Disables the
‘
High Pressure
’
shutdown fault in the event of a feed pressure sen-
sor failure.
System Stall Fault:
Disables the
‘
System Stalled
’
shutdown fault in the event of a failed rotoflow sen-
sor. System stalled alarms occur when the control board does not sense any product water being pro-
duced, and shuts down to protect the pump from running dry.
Poor Quality Fault:
Disables the
‘
High Salinity
’
shut down fault in the event that the salinity probe has
failed or cannot be calibrated within range.
NOTE: The diversion valve will always be active when
this fault is disabled. ALWAYS VERIFY PRODUCT QUALITY BEFORE DRINKING. Serious health
risks may occur.
Prefilter Fault:
Disables the
‘
Service Prefilter
’
shut down fault in the event that the boost pressure sen-
sor has failed or cannot be calibrate within range.
CAUTION: Permanent damage to the feed pump
can occur if this fault is disabled, use caution when operating this system with this fault disa-
bled.
User Settings
Spectra Connect Settings, Cont
’
d
Fault Alarms
Summary of Contents for LB-1800C