18
Tank Level Sensor Calibration
(with optional transducer installed)
1. With a full tank, press the Menu Button
2. Press the Calibrate Sensors Button
3. Press the Tank Level 1 button
4. Press to enter the tank height
Installing the optional tank level sensor (EL
-
SSR
-
5PSI) will allow the control to display
tank levels in up to two tanks. Follow the steps below to enter the calibration sequence
for the optional Tank Level Sensor(s).
The tank needs to be full to proceed with the calibration process and you need to
measure the approximate height of the tank.
5. Enter the height
8.
If the entry is correct press Proceed.
8.
Press OK to save the settings
Press the Feet (Meter) field to enter the
tank height in feet (meters).
Press the Inch (cm) field to enter the
height in inches.
Ex: If the Tank height is 150cm:
Enter
‘1’
in the field labeled
‘
Meter
’
Enter
‘50’
in the field labeled
‘
cm
’