Appendix A. Specifications
84
220-Volt AC Power Cord for International Use
The criteria for an international 220-volt AC power cord are as follows:
•Power cord must have an attachment plug of the proper type, rating, and safety
approval for the intended country.
•Power cord must have an IEC type CEE-22 female connector on one end to connect
the library.
•Cord must be a flexible, HAR (harmonized) type H05VV-F, three conductor, cord
with minimum conductor size of 0.03 square inches (1.0 square millimeters).
Fuses
The library includes two 1/4” x 1 1/4” or 5x20 mm (3AG), 250-volt, 2A slow fuses. For
complete instructions on replacing fuses, see
Caution:
For continued fire protection, replace fuses only with the
specified type and rated fuses.
Operating Environment Limits
Place the library and media in a reasonably controlled environment that does not
exceed the environment limits listed in the table below:
Condition
Minimum
Maximum
Operating Temperature
(Ambient Outside Library)
2
°
C
30
°
C
Storage Temperature
-40
°
C 65
°
C
Relative Humidity (non-condensing)
20%
80%
Max. wet bulb temperature
N/A
26
°
C
Altitude
0 m
(sea level)
3,000 m (9,842
ft)