![Speck pumpen BADU BADUJET Turbo Pro Translation Of Original Operation Manual Download Page 44](http://html.mh-extra.com/html/speck-pumpen/badu-badujet-turbo-pro/badu-badujet-turbo-pro_translation-of-original-operation-manual_1341777044.webp)
Faults
44 EN
08|2020
7 Faults
NOTICE
The magnet-coupled drive unit is mounted on slide bearings.
When the plain bearing is run dry it creates warmth and both the
plain bearing and pump parts are damaged.
Ensure that the pump/unit is always filled with the pump
media. This also applies to checking the rotation direction.
7.1 Overview
Problem:
Motor does not start
Possible cause
Solution
Error protection device has
tripped.
Switch
the
circuit
breaker
back on.
Have it checked by an
electrician.
Frequency converter not
connected correctly.
Plug the connection
correctly (bayonet catch).
Problem:
Piezo button does not light
Possible cause
Solution
Cable wired incorrectly.
Check and set correctly.
Sensor defective.
Check and replace if
necessary.
Problem:
Radio transmitter does not work
Possible cause
Solution
Battery inserted incorrectly or
dead.
Insert battery the right way
round.
Replace
battery.
Transmitter immersed in water
for too long.
Remove batteries and dry
the transmitter at max.
40 °C.
Replace batteries if
necessary.
Problem:
Fuse in the house distributor trips
Possible cause
Solution
Wrong or fast fuse installed.
Check
connections.
Use 16 A slow-blow fuse.
Summary of Contents for BADU BADUJET Turbo Pro
Page 1: ...EN EN Translation of original operation manual Submerged counter swim unit ...
Page 20: ...Installation 20 EN 08 2020 Pool cutout for concrete pools formwork Fig 4 ...
Page 21: ...Installation 08 2020 EN 21 Installation of formwork for concrete pools Fig 5 ...
Page 34: ...Installation 34 EN 08 2020 5 4 4 Control cable wiring diagram Fig 18 ...
Page 49: ...Technical Data 08 2020 EN 49 10 2 Exploded drawing Fig 26 ...