Commissioning/Decommissioning
08|2020 EN
43
6.2.3 Ball
nozzle
The nozzle (42) alignment can be set using the pipe Ø25 included
in the scope of supply. The direction of the ball nozzle is
individually adjustable. The nozzle (42) must usually be set
horizontally.
If it is stiff, the nozzle (42) can be loosened and adjusted by
undoing the three Phillips tapping screws (46) with a suitable
screwdriver. Insert the Phillips screwdriver through the respective
guide hole on the stainless steel panel (3x) and push through to
the screw.
6.3 Shutting
down
1. Switch off the system and disconnect from the mains.
2. Lower the water level in the swimming pool to the lower edge
of the panel.
6.3.1 Wintering
over
For outdoor countercurrent systems which could be endangered
by frost during the winter.
Active overwintering:
Formation of ice can be prevented by circulating the water by
connecting a filter pump to the nozzle (c).
Passive overwintering:
1. Lower the water level at least to the lower edge of the panel.
2. Pull out the complete drive unit (including the motor) after
loosening the 10 tapping screws (37) and store in a dry room.
3. It is also recommended to remove the stainless steel panel
(55) to protect it from getting dirty during the winter months.
Summary of Contents for BADU BADUJET Turbo Pro
Page 1: ...EN EN Translation of original operation manual Submerged counter swim unit ...
Page 20: ...Installation 20 EN 08 2020 Pool cutout for concrete pools formwork Fig 4 ...
Page 21: ...Installation 08 2020 EN 21 Installation of formwork for concrete pools Fig 5 ...
Page 34: ...Installation 34 EN 08 2020 5 4 4 Control cable wiring diagram Fig 18 ...
Page 49: ...Technical Data 08 2020 EN 49 10 2 Exploded drawing Fig 26 ...