49
Type of motor enclosure
IP X4
Thermal class
F
Motor speed approx. (rpm)
2840
Max. water temperature (°C)
60
Max. casing interior pressure (bar) 2,5
Characteristics
BADU
®
90,
BADU
®
90-AK
50 Hz, n = 2840 min
-1
applicable for water
of 20°C
1)
For standard voltage according to IEC 60038
and DIN EN 60034 (Euro-voltage).
Suitable for continuous operation at 1~ 220-240 V
3~ Y/
Δ
380-420 V / 220-240 V
Tolerances ± 5%.
GS-tested pumps according to EN 60335-1.
2)
Measured with a phonometer according to DIN 45635.
3)
Inside thread according to DIN 2999 Part 1 and
ISO 7/1, seal only with Teflon tape.
KL 90.009-6
Total dynamic head H (m)
Flow rate Q (m
3
/h)
4
0
2
20
10
5
15
90/13
25
30
90/15
40
6
8
10
12
14
16
18
20
90/7
90/11
90/20
n=2840min
-1
Technical data at 50 Hz BADU 90
7 / 7-AK
11 / 11-AK 13 / 13-AK 15 / 15-AK 20 / 20-AK
Inlet/outlet (RP)
3)
1
1
/
2
/ 1
1
/
2
1
1
/
2
/ 1
1
/
2
2 / 1
1
/
2
2 / 1
1
/
2
2 / 1
1
/
2
Recommended inlet/outlet pipe, PVC pipe, d
50/50
50/50
63/50
63/50
63/63
Power input P
1
(kW)
1~ 230 V
0,50
0,69
0,85
1,10
1,40
Power output P
2
(kW)
1)
1~ 230 V
0,30
1)
0,45
1)
0,55
1)
0,75
1)
1,00
1)
Rated current (A)
1~ 230 V
2,40
3,00
4,00
5,20
6,70
Sound pressure Level in 1 meter distance
2)
Lpa (1m)/dB(A)
1~ 230 V
51,1
51,7
52,3
55,5
62,2
Acoustic capacity
Lwa (1m)/dB(A)
1~ 230 V
59
60
60
64
70
Power input P
1
(kW)
3~ Y/
Δ
400/230 V
0,44
0,66
0,75
1,00
1,32
Power output P
2
(kW)
1)
3~ Y/
Δ
400/230 V
0,30
1)
0,45
1)
0,55
1)
0,75
1)
1,00
1)
Rated current (A)
3~ Y/
Δ
400/230 V
0,95/1,65
1,25/2,15
1,55/2,70
2,10/3,60
2,50/4,30
Sound pressure Level in 1 meter distance
2)
Lpa (1m)/dB(A)
3~ Y/
Δ
400/230 V
51,8
51,9
54,5
54,0
58,2
Acoustic capacity
Lwa (1m)/dB(A)
3~ Y/
Δ
400/230 V
60
60
63
62
66
Weight (kg)
1~
9,2
9,2
11,0
13,0
16,0
Weight (kg)
3~
9,0
9,0
11,0
12,2
12,3
Summary of Contents for BADU 90