GB
26
Subject to modification and errors without notice
* From components that are combustible or need to be protected.
Varia
2Lh H
2
O /
2Rh H
2
O
Varia
2Lh H
2
O /
2Rh H
2
O
(Export)
Nova E
H
2
O
Nova
F-Air
Renova
A H
2
O
Renova
B-Air
Renova
C-Air
(split logs)
Renova
C-Air
(Lignite)
General data
Norminal heat output (kW) (closed structure)
10,4 /
water output 6,0
14,7 /
water output 8,4
14,0 /
water output 9,0
10,1
13,4 /
water output 6,9
8,8
8,5
7,8
Thermal output range (kW)
7,3 - 13,5
10,3 - 19,1
9,8 - 18,2
7,1 - 13,1
9,4 - 17,4
6,2 - 11,4
6,0 - 11,1
5,5 - 10,1
Efficiency (%)
> 80
> 80
> 80
> 80
> 80
> 80
> 80
> 80
Recommended flue diameter (mm)
200
200
180
180
180
180
150
150
Flue outlet diameter (mm)
200
200
180
180
180
180
150 / 160 / 180 150 / 160 / 180
Weight (kg) (approx.)
380
380
290
190
200
140
110
110
required minimum cross section for circulating air with WAC
-
-
-
-
-
-
-
-
required minimum cross section for circulating air
260 / 280
260 / 280
370 / 450
1580 / 1900
690 / 830
1420 / 1700
1030 / 1240
1030 / 1240
Operation with open
door (multiple usage
of the chimney not
permitted)
Exhaust mass flow (g/s)
-
-
-
-
-
-
-
-
Exhaust gas temperature (°C)
-
-
-
-
-
-
-
-
Exhaust gas temperature behind NSHF (°C)
-
-
-
-
-
-
-
-
Required manometric pressure (Pa)
-
-
-
-
-
-
-
-
Recommended diameter in opening to secure sufficient air into the room (cm)
-
-
-
-
-
-
-
-
Operation with closed
door (multiple usage
of the chimney
permitted)
Exhaust mass flow (g/s)
10,8
12,2
12,7
9,5
12,8
9,4
8,2
8,2
Exhaust gas temperature (°C)
285
265
400
355
396
357
495
483
Required manometric pressure (Pa)
12
12
12
12
12
12
12
12
CO
2
(%)
8,2
8,2
8,2
8,1
7,7
7
7,7
7,7
Necessary area to secure air balance in the room (M-FeuVO) (cm)
15
15
15
15
15
15
15
15
Combustion air requirement (m
3
/h)
49,8
53,4
46,3
34,1
47,3
34,7
30,3
30,3
Heat distribution
Convection (%)
6
6
14
78
24
81
66
66
Glass window (%)
37
37
22
22
23
19
34
34
Water (%)
57
57
64
-
53
-
-
-
Distances to convec-
tion chamber
To the wall (cm)
3
3
6
10
6
10
10
10
To the floor (cm)
-
-
-
-
-
-
-
-
Thermal insulation*
(Example rock wool
mats in acc. with
AGI-132 Q)
Mounting wall (cm)
5
5
10
13
12
13
15
15
Floor (cm)
-
-
-
-
-
-
-
-
Lateral wall (cm)
5
5
10
13
12
13
15
15
Additional walling for wall protection (cm)
10
10
6
6
6
6
6
6
Tests and values
Type A - (no self-closing door)
-
-
-
-
-
-
-
-
Type A1 - (self-closing door)
BImSCHV. 1st level
BImSCHV. 2nd level
15a BVG
Summary of Contents for Arte 1Vh