General data
Norminal heat output (kW) (closed structure)
7,0
7,0
7,0
11,0
7,0
12,0
8,0
9,0
Thermal output range (kW)
4,9 - 9,1
4,9 - 9,1
4,9 - 9,1
7,7 - 14,3
4,9 - 9,1
8,4 - 15,6
5,6 - 10,4
6,3 - 11,7
Efficiency (%)
> 80
> 80
> 80
80
> 78
80
> 80
> 78
Recommended flue diameter (mm)
180
180
180
200
200
200
180
250
Flue outlet diameter (mm)
180
180
180
200
200
200
180
250
Weight (kg) (approx.)
240
245
245
270
270
270
230
250
required minimum cross section for circulating air with WAC
-
-
-
700
-
700
700
700
required minimum cross section for circulating air
860 / 985
810 / 970
810 / 970
1250 / 1500
750 / 900
1280 / 1540
1220 / 1470
890 / 1070
Operation with open
door (multiple usage
of the chimney not
permitted)
Exhaust mass flow (g/s)
36,8
-
-
21,2
-
-
-
18,4
Exhaust gas temperature (°C)
170
-
-
270
-
-
-
240
Exhaust gas temperature behind NSHF (°C)
-
-
-
-
-
-
-
-
Required manometric pressure (Pa)
12
-
-
14
-
-
-
10
Recommended diameter in opening to secure sufficient air into the room (cm)
-
-
-
64
-
-
-
69
Operation with closed
door (multiple usage
of the chimney
permitted)
Exhaust mass flow (g/s)
6,1
6,5
6,5
9,6
7,7
10
7,5
8,8
Exhaust gas temperature (°C)
325
276
276
350
245
218
255
340
Required manometric pressure (Pa)
12
12
12
12
12
12
12
12
CO
2
(%)
10,8
9,7
9,7
10
8,3
10
9,2
9,7
Necessary area to secure air balance in the room (M-FeuVO) (cm)
15
15
15
15
15
15
15
15
Combustion air requirement (m
3
/h)
19,7
22,6
22,6
36,5
33,5
36,5
25,8
28,4
Heat distribution
Convection (%)
42
50
95
53
51
53
56
52
Glass window (%)
58
50
5
47
49
47
44
48
Water (%)
-
-
-
-
-
-
-
-
Distances to convec-
tion chamber
To the wall (cm)
10
7
7
12
8
13
12
9
To the floor (cm)
-
-
-
-
-
-
-
-
Thermal insulation*
(Example rock wool
mats in acc. with
AGI-132 Q)
Mounting wall (cm)
13
15,5
-
7
13
7
11
8
Floor (cm)
-
-
-
-
-
-
-
-
Lateral wall (cm)
9
6,2
-
7
11
7
9
8
Additional walling for wall protection (cm)
10
10
-
10
10
10
10
10
Tests and values
Type A - (no self-closing door)
-
-
-
-
Type A1 - (self-closing door)
BImSCHV. 1st level
BImSCHV. 2nd level
15a BVG
Summary of Contents for Arte 1Vh
Page 1: ...Installation Instructions Fireplace Inserts ...
Page 27: ...GB 27 NOTES GB ...
Page 28: ...GB 28 NOTES ...