GB
16
Subject to modification and errors without notice
* From components that are combustible or need to be protected.
Speedy
1V / 1Vh 51
NSHF
Speedy
1V / 1Vh 51
(Export)
Speedy
1V / 1Vh 57
Speedy
1V / 1Vh 57
NSHF
Speedy
1V / 1Vh 57
(Export)
Varia
1V / 1Vh 51
Varia
1V / 1Vh 51
(Export)
Varia
1V / 1Vh 57
General data
Norminal heat output (kW) (closed structure)
10,0
14,5
9,0
10,0
14,5
11,0
17,5
11,0
Thermal output range (kW)
7,0 - 13,0
10,2 - 18,9
6,3 - 11,7
7,0 - 13,0
10,2 - 18,9
7,7 - 14,3
12,3 - 21,2
7,7 - 14,3
Efficiency (%)
> 80
> 78
80
> 80
> 78
> 80
> 78
> 80
Recommended flue diameter (mm)
200
200
200
200
200
200
200
200
Flue outlet diameter (mm)
200
200
200
200
200
200
200
200
Weight (kg) (approx.)
200
200
200
200
200
245
245
245
required minimum cross section for circulating air with WAC
700
700
700
-
700
700
700
700
required minimum cross section for circulating air
1420 / 1710
1420 / 1710
1420 / 1710
1420 / 1710
1420 / 1710
1420 / 1710
1420 / 1710
1420 / 1710
Operation with open
door (multiple usage
of the chimney not
permitted)
Exhaust mass flow (g/s)
-
-
-
-
-
-
-
-
Exhaust gas temperature (°C)
-
-
-
-
-
-
-
-
Exhaust gas temperature behind NSHF (°C)
-
-
-
-
-
-
-
-
Required manometric pressure (Pa)
-
-
-
-
-
-
-
-
Recommended diameter in opening to secure sufficient air into the room (cm)
-
-
-
-
-
-
-
-
Operation with closed
door (multiple usage
of the chimney
permitted)
Exhaust mass flow (g/s)
8,8
10,2
7,5
8,8
10,2
9,6
13,1
9,0
Exhaust gas temperature (°C)
391
346
288
392
327
288
330
305
Required manometric pressure (Pa)
12
12
12
12
12
12
12
12
CO
2
(%)
10,0
13,2
11,7
10,0
13,2
10,9
12,2
11,8
Necessary area to secure air balance in the room (M-FeuVO) (cm)
15
15
15
15
15
15
15
15
Combustion air requirement (m
3
/h)
27,7
49,2
35,6
33,8
33,1
36,1
57,5
36,1
Heat distribution
Convection (%)
64
64
64
64
64
65
65
62
Glass window (%)
36
36
36
36
36
35
35
38
Water (%)
-
-
-
-
-
-
-
-
Distances to convec-
tion chamber
To the wall (cm)
10
10
10
10
10
10
10
10
To the floor (cm)
-
-
-
-
-
-
-
-
Thermal insulation*
(Example rock wool
mats in acc. with
AGI-132 Q)
Mounting wall (cm)
16
16
16
16
16
13
13
11
Floor (cm)
-
-
-
-
-
-
-
-
Lateral wall (cm)
16
16
16
16
16
13
13
13
Additional walling for wall protection (cm)
10
10
10
10
10
10
10
10
Tests and values
Type A - (no self-closing door)
-
Type A1 - (self-closing door)
BImSCHV. 1st level
BImSCHV. 2nd level
15a BVG
Summary of Contents for Arte 1Vh
Page 1: ...Installation Instructions Fireplace Inserts ...
Page 27: ...GB 27 NOTES GB ...
Page 28: ...GB 28 NOTES ...