Spartherm ambiente 5 Installation And Operating Manual Download Page 1

Installation and Operating Manual

ambiente stoves

Summary of Contents for ambiente 5

Page 1: ...Installation and Operating Manual ambiente stoves...

Page 2: ...onal level creating feelings of security and comfort To ensure this is achieved we recommend that you carefully read these operating instructions so that you can become quickly and comprehensively acq...

Page 3: ...quirements for Installation of the ambiente a4 H2O 21 2 9 3 Thermal discharge safety device ambiente a4 H2O 22 2 9 4 Thermal pump control ambiente a4 H2O 22 2 9 5 Electrical Connection 23 2 9 6 Connec...

Page 4: ...omply with national and European standards the relevant country specific and local guidelines and regula tions and in Germany the relevant Heating Regulation FeuVO of the state where you live The stov...

Page 5: ...mbiente a4 H2O only 1 2 DAMAGE IN TRANSIT Please inspect the goods immediately upon delivery visual check Any damage should be noted on your delivery note You should then inform your stove fitter Prot...

Page 6: ...e ambiente a1 a2 a3 a4 a4H2O a5 a7 a8 stove is a non room air sealed open flue fireplace Problems may therefore arise if the stove is operated at the same time as a ventilation system such as a kitche...

Page 7: ...4 H20 a5 a7 a8 RLA RLU RLA RLU RLA RLA RLA Max permissible flow tempera ture C 105 105 Max operating temperature C 95 2 95 2 Minimum return temperature C 60 60 Water output resistance at 650 l h mbar...

Page 8: ...pal ordinance yes yes yes yes yes yes yes 15a for Austria yes yes yes yes yes yes yes Clean Air Ordinance from 01 2011 for Switzerland yes yes yes yes yes yes yes 3 Refer to section 2 5 Fire Precautio...

Page 9: ...bled as ordered The flue gas outlet will be fitted at the rear unless otherwise specified at the time of ordering If the position subsequently has to be changed the following steps should be carried o...

Page 10: ...he rear flue gas connection cover panel Fig 2f Item B Undo the screws and remove the cover plate Fig 2g Items B and C Then dismantle the top flue gas outlet connecting sleeve Start by undoing the scre...

Page 11: ...ver plate to the rear flue gas connection Fig 4c Finally replace the cover panel in position Fig 4d Fig 3a Fig 3b Fig 3c Fig 3d Fig 2i Items E and G Finally fit the top flue gas connection cover the c...

Page 12: ...rear of the screen Fig 5b Item B Now fit the screen around the swivel connector The screen has to be pulled apart at the join to do this After placing the screen in position re insert the two screws...

Page 13: ...stones Start by installing the front stone A Next fit the supporting plate B Fig 6a Fitting the storage stones ambiente a3 with top and side flue gas connection Place the three shallow stones in posit...

Page 14: ...de a cosy warmth even when the fire has gone out A Front stone B Supporting plate C Convective heat to room D Connecting sleeve E Cover F Convective heat to storage stones G Convection air adjustment...

Page 15: ...f the windows and doors are sealed e g in connection with energy saving measures the fresh air supply may be restricted and that can adversely affect the stove s draught This can be detrimental to you...

Page 16: ...ssembled The stove covering can be opened up for the purpose unscrew the cover cap and the connecting piece can be screwed on If a pipe connection is attached to the combustion air coupling the combus...

Page 17: ...ection Now care fully lift off the stove covering Fig 8a Next unscrew the screw cap Fig 8b Connect the combustion air connecting piece to the flexible extensible combustion air duct installed on site...

Page 18: ...dered a combustible building component and does not require any special precautions Please note that the minimum distances indicated from rear walls and side walls need to be adapted for rotating stov...

Page 19: ...E cm Combustible Protection not needed Combustible Protection not needed Combustible Protection not needed Length x width Distance round floor covering ambiente a1 15 10 10 5 80 80 50 x 30 50 66 ambi...

Page 20: ...with the regulations The basic rule is that the connecting piping should be installed in such a way that it can be cleaned at any time This should be ensured by providing an appropriate number of cle...

Page 21: ...The connections are labelled and should not be used other than as indicated In particular the integral safety device safety heat exchanger should not be used to heat water To facilitate installation o...

Page 22: ...omponents included in the system must be read and observed when installing the stove 2 9 3 THERMAL DISCHARGE SAFETY DEVICE ambiente a4 H2O As the ambiente a4 H2O heating system cannot be quickly switc...

Page 23: ...ambiente a4 H2O s water heat exchanger As an option the temperature can be adjusted by the installation contractor if circumstances demand This is done by adjusting the circular disc or removing the t...

Page 24: ...first time with the aid for example of hot water from a kettle and a thermometer Note that the rear cover panel has to be removed in order to do this 2 9 6 CONNECTING THE ambiente a4 H2O TO A HEATING...

Page 25: ...hanger drain IG R Safety heat exchanger inlet IG S Heat exchanger vent 3 8 T Non return valve However the pipes should be dimensioned by the specialist firm taking local conditions into account The am...

Page 26: ...ng in the buffer tank and pipes or radiation losses from the system components etc Such factors extend the buffer tank heating up time in practice 2 9 7 LOAD UNIT HEAT CHARGER IN THE ambiente a4 H2O S...

Page 27: ...or handle and control handle the viewing pane the flue ducts etc These parts can get very hot Always take appropriate precautions when touching or operating hot stove parts e g use the protective glov...

Page 28: ...ed 180 i e 90 to the left and 90 to the right Fig 15a To rotate the stove turn the lever see Fig 15b After rotating the stove to the desired position raise the lever and turn it to the right to lock t...

Page 29: ...ontain residual moisture at commissioning Slowly increase the heat output the next 3 to 5 times the stove is lit up to about 30 above the nominal output to allow the anti corrosion coating on the surf...

Page 30: ...or damage the floor underneath the stove An absorbent material should therefore be placed under the stove the first few times it is used until there is no more condensate leakage Only a moderate fire...

Page 31: ...on which minimises sooting up of the glass This is the normal position during combustion The exact position depends on local conditions and can be adjusted by the operator according to how the stove i...

Page 32: ...and it should stay in that position for at least another 20 30 minutes to get the stove up to operating temperature 10 More information about how much wood to put on the fire can be found in section...

Page 33: ...o keep your stove operating efficiently even after years of use it is essential to stoke the stove correctly To avoid the risk of overheating do not exceed the maximum heat output Please refer to sect...

Page 34: ...andard 18893 Simply put favourable describes a situation where the room has only one external wall and otherwise mainly adjoins heated internal rooms whereas unfavourable refers to a room with two ext...

Page 35: ...t the flue gas temperature dropping too low 5 FUEL The foundation Wald in Not Forest in Danger put it aptly in one of their information brochures Wood does not cause any burden for nature Wood is stor...

Page 36: ...nd timber used 5 1 1 STORING WOOD In general it is recommended to store firewood for approx 2 3 years the wood should be protected from dampness and well ventilated e g under a roof overhang on a side...

Page 37: ...e connecting flue pipes to the chimney must be inspected for deposits and if necessary cleaned at regular intervals on a yearly basis and also perhaps during and after the heating season and after the...

Page 38: ...r char This can lead to soiling of the installation room and the furniture within 6 1 1 CLEANING THE WATER HEAT EXCHANGER IN THE ambiente a4 H2O Cleaning the water heat exchanger is essential The stov...

Page 39: ...p phase it is normal for the lining to be covered by a dark coating Once the operating temperature is reached this layer on the firebox lining will have burnt off Cracks are not considered grounds for...

Page 40: ...reclay set without baffle plate 1014340 1018734 1024592 1024593 Accessories Ash grate small 220 160 mm 1006404 1006404 Ash pan small 220 150 mm 1004809 6 3 CHIMNEY FIRE When burning wood especially so...

Page 41: ...e any parts 6 4 1 MAINTENANCE OF THE WATER HEAT EXCHANGER IN THE ambiente a4 H2O Carrying out maintenance on the ambiente a4 H2O is essential The ambiente a4 H2O can only achieve its full effectivenes...

Page 42: ...If this did not occur from the very beginning please check the following points Are the correct fuel and technology being used Is the wood dry enough Is the wood too thick Has the air intake been suff...

Page 43: ...evice observe the minimum flow rate Radiators are not heating up Radiators that are not located in the installation room are cold Radiator thermostats close when the set room temperature is achieved T...

Page 44: ...s around the fire such as fireclay bricks vermiculite fire grates seals and glass ceramics 8 4 REQUIREMENT OF EFFECTIVENESS FOR THE WARRANTY The warranty period starts on the date of delivery to the d...

Page 45: ...of defects shall take precedence This warranty undertaking expressly does not cover further compensation exceeding the statutory guarantee 8 7 EXTENSION OF WARRANTY In the case of performance in accor...

Page 46: ...iewing panes or operating noise Trial firing carried out Yes No The user of the stove has been instructed in its operation and the installation and operating instructions have been handed over Signatu...

Page 47: ...heating system Yes No Functional test completed Yes No Test fire completed Yes No Actual manometric pressure tested Yes No Negative pressures greater than 20 25 Pa may interfere with correct operatio...

Page 48: ...BR The global brand for your living room Your specialist dealer Reg Nr Goods checked by Date Day Month Year Spartherm Feuerungstechnik GmbH Maschweg 38 D 49324 Melle Phone 49 0 5422 94 41 0 Fax 49 0...