42
6.6.2
Special functions - "Extended submenu"
Various parameters can be adapted via this submenu, which is especially helpful when e.g. using an
external control system.
To access the submenu, the following procedures are necessary:
Simultaneously press function keys "Arrow up" and "Arrow down" and keep them pressed.
Switch on stud welder with main switch.
Parameter Description
Range
Default
value
Trg.Del.
Trigger delay. Start of the welding process via the
trigger key or CNC interface is delayed.
0 – 2000 ms
0
aut.ld.
Automatic deactivation of the automatic stud reload
process.
on - off
on
Lift
Extension of lift time. Here you can prolong the
specified “Lift time” prior to the welding process.
0 – 2000 ms
0
Res-Err.
Automatic error reset. Here you can set a time after
which the error signal will be deleted automatically.
When setting “0”, the error signal won’t be automatically
deleted.
0 – 2000 ms
0
Batt.
Capacitance switch-over 1 = 33,000 µF | 2 = 99,000 µF
1 - 2
2
Rdy.
This function applies to BMK feeders only
Rdy = off:
The "Ready signal/LED" is displayed after
reloading when the blow air time is over.
Rdy = on:
The "Ready signal/LED" is displayed after
reloading when the blow air time is over and a new stud
inserted in the feed rail of the stud feeder and is ready
to be fired.
on - off
off
Summary of Contents for BMS-10P