17
p-Select – interface
Communication interface for the P3-Select/S gun distribution system. This interface serves for the
automatic selection of programs (for further information, please refer to the operating instructions of the
P3-Select gun distribution system).
Feeder – interface
The feeder interface serves as the control and communication of our systems for the automatic stud
reload of e.g. UVR-300 SOYER universal feeders.
Isolated ground receptacle 3.15 A
The isolated ground receptacle exclusively serves as power supply for our universal feeders or
additional accessories such as welding heads.
NOTE
The operating voltage of the isolated ground receptacle corresponds to the current
mains voltage.
CAUTION
The isolated ground receptacle is protected by 3.15 A. Never connect any additional
"appliances" such as stud welders.
Setting the mains voltage for 115 V or 230 V
The BMS-10P stud welder is suitable for two power supply voltages: 115 V or 230 V.
The factory-set mains connection values are indicated on the type plate of the welding equipment.
The mains voltage can be changed by reconnecting the corresponding connection terminals at the
mains transformer.
For further information, please contact your responsible SOYER service office.
CAUTION
If the operating voltage is changed by reconnecting the connection terminals at the
mains transformer, the specifications on the type plate have to be changed
accordingly.
CAUTION
Only authorized specialist electricians are allowed to carry out works at the electric
mains supply!