21
5.1.4 Description
of
display
A parameter designation is shown blinking in the display to indicate that its value can be
altered using the keyboard.
Example of a display shown after stud welder has been switched on
:
The measured charging voltage of the capacitor bank is displayed
at the top right
.
Example: |101
Current charging voltage is 101 V
The current capacity of the capacitor bank is displayed
at the bottom right
.
Example BMS-10P: B1 = 33,000 µF | B2 = 99,000 µF
Description of operating parameters (MODE)
Parameter Description
OP
Operation. Standard setting for normal welding operation. The parameters of the
programs can only be altered in this mode.
LIFT
Lift test. It allows activating the lifting magnet of the gun/head to control the setting
without welding operation
.
MEAS
The operating mode "MEAS" allows you to determine the desired values for a welding
program (pls. refer to the description of the quality control).
Setting options for welding operation (OP)
Parameter Description
Range
PG
Number of the set program.
1 - 6
STUD
Stud type. Only serves as information and has no effect on the weld. M3 – M8
VOLT
Adjusted charging voltage of the capacitor battery in volt.
Please note:
In addition, the measured charging voltage of the capacitor battery
will also be shown on the display.
60 – 200 V
RLT
Reload time in milliseconds (only with automatic operation)
0 - 9900 ms
TL
Tolerance. Admissible deviation of quality control.
O = Quality control is switched off.
1 = minimum tolerance limit, 10 = maximum tolerance limit
0 - 10