41
6.6 Special
functions
The following additional special functions can be selected with the BMS-10P stud welder:
NOTE
Only select the special functions when you are already familiar with the basic functions of
the stud welder.
The stud welder must be switched off to call up special functions. To call up the respective special
functions, certain key combinations must be pressed and kept pressed while switching the stud welder
on. For terminating the special function, switch off the stud welder with the main switch.
Now the stud welder can be set into operation again.
The following special functions are available:
6.6.1
Special function "Deleting RAM"
This special function serves as "RESET function" for the stud welder e.g. for eliminating errors or
when initiating the stud welder for the first time. All settings and programs in the random access
memory (RAM) are deleted.
.
NOTE
In this process, all your personal user programs are deleted as well. These programs
must be entered again. When using the quality control, new reference values have to be
determined.
For deleting the random access memory, please proceed as follows:
Simultaneously press function keys "Arrow up", "Arrow down", " Arrow right" and "Arrow left"
and keep them pressed.
Switch on stud welder with main switch.
Switch off the stud welder with main switch and switch on again.
The stud welder is now operative.