4 Installation of the stud welding system
Only install the stud welder on an even surface. The pads located on the bottom of the
welding equipment guarantee its anti-skid position and serve as vibration dampers.
Although the stud welder is resistant to environmental influences, it should be protected
against dampness and dust.
Please pay particular attention to the bearing strength of the workshop furniture and ensure a
safe and stable position for the welding equipment.
Make sure there is sufficient free space around the air apertures, otherwise the device safety
mechanism will respond and interrupt the welding process.
Install the stud welder close to the welding location.
Ensure sufficient ventilation of the working room when operating the welding system.
NOTE
The casing of the stud welder corresponds to safety class IP 21. Please note that this
system of protection is not suitable for operation or transportation in the rain.
Ensure correct connected loads for electrical connections as indicated on the type
plate.