13
Specifications
NOTE:
Accuracy is stated at 65°F to 83°F (18°C to 28°C) and less than 70% RH.
Input Impedance: 10M
Ω
. Maximum Input: 1000V DC or 1000V AC rms.
Function Range Resolution Accuracy (% of reading)
DC Voltage
(Auto-ranging)
400.0mV
4.000V
40.00V
400.0V
1000V
0.1mV
1mV
10mV
100mV
1V
± 0.5% of rdg ± 3 digits
± 1% of rdg ± 3 digits
Input Impedance: 10M
Ω
.
AC Response: 50Hz to 400Hz
Maximum Input: 1000V DC or 1000V AC rms.
All AC voltage ranges are specified from
5% of range to 100% of range
AC Voltage
(Auto-ranging)
400.0mV
4.000V
40.00V
400.0V
1000V
0.1mV
1mV
10mV
100mV
1V
± 1.0 % of rdg ± 8 digits
± 1.2% of rdg ± 8 digits
Overload Protection: FF500mA / 1000V and F10A / 1000V Fuse
AC Response: 50Hz to 400Hz
Maximum Input: 4000uA AC rms. on uA, 400mA AC rms. on mA, 10A AC rms. on 10A range
AC Current
(Auto-ranging)
400.0uA
4000uA
40.00mA
400.0mA
10A
0.1uA
1uA
10uA
100uA
10mA
± 1.2% of rdg ± 5 digits
± 2.5% of rdg ± 5 digits
Overload Protection: FF500mA / 1000V and F10A / 1000V Fuse
DC Current
(Auto-ranging)
400.0uA
4000uA
40.00mA
400.0mA
10A
0.1uA
1uA
10uA
100uA
10mA
± 1.0% of rdg ± 3 digits
± 2.5% of rdg ± 3 digits
Maximum Input: 4000uA DC on uA range, 400mA DC on mA range, 10A DC on 10A range
14
Specifications
Input Protection: 1000V DC or 1000V AC rms.
Function Range Resolution Accuracy (% of reading)
Resistance
Ω
(Auto-ranging)
400.0
Ω
4.000k
Ω
40.00k
Ω
400.0k
Ω
4.000M
Ω
40.00M
Ω
0.1
Ω
1
Ω
10
Ω
100
Ω
1k
Ω
10k
Ω
± 0.8% of rdg ± 5 digits
± 0.8% of rdg ± 2 digits
± 2.5% of rdg ± 8 digits
Sensitivity: >3V RMS while
≤
1MHz ;
Sensitivity: >8V RMS while >1MHz ;
Input Protection: 1000V DC or 1000V AC rms.
Frequency
(Auto-ranging)
4.000Hz
40.00Hz
400.0Hz
4.000KHz
40.00kHz
400.0kHz
10.00MHz
0.001Hz
0.01Hz
0.1Hz
1 Hz
10Hz
100Hz
1kHz
± 1.0% of rdg ± 3 dgts
± 1.2% of rdg ± 4 dgts
Input Protection: 1000V DC or 1000V AC rms.
Capacitance
(Auto-ranging)
40.00nF
400.0nF
4.000uF
40.00uF
100.0uF
40.00mF 10 mF ± 5.0% of rdg ± 7 dgts
10pF
0.1nF
1nF
10nF
0.1uF
± 5.0% of rdg ± 7 dgts
± 3.0% of rdg ± 5 dgts
± 5.0% of rdg ± 7 dgts