Operation

RANGE Button

When the meter is first turned on, it goes into the Autoranging mode.

This automatically selects the best range for the measurements being made

and is generally the best mode for most applications. For measurement

situations requiring that a range be manually selected, perform the following:

1. Press the 

RANGE

 button. The “

AUTO

” display indicator will turn off.

2. Press the 

RANGE

 button to step through the available ranges until you select 

    the range you want.

3. Press and hold the 

RANGE

 button for 2 seconds to exit the Manual Ranging

    mode and return to Autoranging.

MODE Button

To select 

Ω

/Diode Test/Continuity, AC/DC Voltage, AC/DC Current.

MAX/MIN Button 

The MAX/MIN function allows the meter to capture the highest and lowest

measurement for later reference. (MIN/MAX is limited to a single range.)

1. Use the 

RANGE

 button to select the proper range for the measurement

    being made.
2.Press the 

MAX/MIN

 button. The indicator 

“MAX” 

or

 “MIN”

 will appear

   in the display.
3. Press the 

MAX/MIN

 button to recall the lowest or highest reading.

4. If the “MAX MIN” message is flashing, the instrument is in MAX/MIN mode

    but not recording, press the 

MAX/MIN

 button to select a mode.

5. To return to normal AUTO measurement mode, press and hold the

    

MAX/MIN

 button for 2 seconds.

HOLD Button

To freeze the reading on the LCD display, momentarily press the 

HOLD 

button.

The “

HOLD

” icon will be displayed on the LCD. Momentarily press the 

HOLD 

button again to return to normal operation.

6

Operation

Backlight Button

The backlight illuminates the display when the ambient light is too low to permit

viewing of the displayed readings. To turn on the backlight, press the “    ” button. 

PEAK Hold button

The Peak Hold function captures the peak AC or DC voltage or current.

It can capture negative or positive peaks as fast as 1 millisecond in duration. 
1. Refer to the manual for Voltage or Current measurements.
2. Connect to the circuit under test.
3. Allow time for the display to stabilize.
4. Press and hold the 

PEAK

 button until “

CAL

” appears on the display.

    This procedure will zero the range selected.
5. Press the 

PEAK

 button, 

Pmax

 will display.

6. The display will update each time a higher positive peak occurs.
7. Press the 

PEAK

 button again, 

Pmin

 will display. 

8. The display will update each time a higher negative peak occurs.
9. To return to normal operation, press and hold the 

PEAK

 button until the

    

Pmin 

or

 Pmax

 indicator switches off.

Auto Power Off

In order to conserve the battery, the meter will turn off approximately after

30 minutes of use. To override Auto Power Off, press and hold the 

PEAK

 button

with the function switch in the OFF position. Turn the function switch to turn

the meter on. Release the 

PEAK

 button. The       symbol on the LCD display

will not be shown; indicating the Auto Power Off is not activated.

To re-activate Auto Power Off, turn the function switch to the 

OFF

 position.

The       symbol will be shown on the LCD display when the meter is turned on. 

Summary of Contents for 12070T

Page 1: ...ciones de uso TESTING EQUIPMENT E361819 12 14 Rev 1 12070T manual Contents Made in China Product distributed by Southwire Company LLC One Southwire Drive Carrollton GA 30119 2014 Southwire Company LLC...

Page 2: ...attery compartment door firmly to maintain the waterproof and dust proof integrity of the meter Loose or overtightened screws or an improperly seated o ring may compromise the meter s water and dust i...

Page 3: ...ines to detached buildings Incoming service entrance from utility Outdoor pumps WARNING Operation is limited to CAT II applications when the insulated tips are removed from one or both test probes Ref...

Page 4: ...icon will be displayed on the LCD Momentarily press the HOLD button again to return to normal operation 6 Operation Backlight Button The backlight illuminates the display when the ambient light is too...

Page 5: ...rallel to the circuit under test For DC measurements touch the red test probe to the positive side of the circuit and the black test probe to the negative side of the circuit 5 Read the voltage on the...

Page 6: ...OL The resistance will be shown on the LCD display if it is below 400 10A 30 sec MAX CAT III 1000V CAT IV 600V FUSED MAX 400mA Temp Auto Power Off Waterproof every 15 min mA COM Hz CAP 12070T Autorang...

Page 7: ...s or an improperly seated o ring may compromise the meter s water and dust ingress protection WARNINGS To avoid electric shock do not operate your meter until the battery and fuse cover are in place a...

Page 8: ...mA 1 2 of rdg 5 digits 2 5 of rdg 5 digits Overload Protection FF500mA 1000V and F10A 1000V Fuse DC Current Auto ranging 400 0uA 4000uA 40 00mA 400 0mA 10A 0 1uA 1uA 10uA 100uA 10mA 1 0 of rdg 3 digit...

Page 9: ...tenance or repair operation outside of specifications or abnormal handling of the product Southwire s sole liability and the purchaser s exclusive remedy for any breach of this warranty is expressly l...

Page 10: ...AC rms 10A DC 1000VAC rms 1000VDC 1000VAC rms 1000VDC Lea entienda y siga todas las Reglas de Seguridad e Instrucciones de Operaci n en este manual antes de usar este metro Las caracter sticas de seg...

Page 11: ...binaci n del metro cables de pruebas y cualquier accesorio conectado al metro y cables de pruebas La combinaci n de clasificaci n es la M S BAJA de cualquier componente individual ADVERTENCIA El funci...

Page 12: ...neamente el bot n HOLD otra vez para regresar a la operaci n normal 6 Bot n de PEAK Hold Retenci n de picos La funci n Peak Hold captura el voltaje o corriente AC o DC m s alto Puede capturar alturas...

Page 13: ...positiva mA 4 Para medidas de corriente hasta 4000 A mueva el interruptor rotatorio a la posici n A e inserte la sonda roja en la entrada positiva A 5 Presione moment neamente el bot n MODO para sele...

Page 14: ...oximadamente 30 o menos sonar un tono Si el circuito est por encima de los 400 la pantalla indicar OL La resistencia aparecer en la pantalla si est por debajo de los 400 10 Prueba de Diodos Nunca comp...

Page 15: ...cubierta trasera y la puerta de compartimiento de la bater a para mantener la integridad de las caracter sticas de impermeabilidad y a prueba de polvo del metro Tornillos flojos o demasiado apretados...

Page 16: ...10uA 100uA 10mA 1 0 de la lectura 3 digitos 2 5 de la lectura 3 digitos Protecci n de Sobrecarga FF500mA 1000V y F10A Fusible 1000V Entrada M xima 4000uA DC en un rango uA 400mA DC en un rango mA 10A...

Page 17: ...uier incumplimiento de esta garant a est limitada expresamente a la reparaci n o reemplazo del producto por parte de Southwire La reparaci n o reemplazo del producto se har bajo la determinaci n de So...

Reviews: