ST2826 Operation manual
Ver1.0
◇
116
:SEQuence:BIN
is used to set the high limit and the low limit of the comparator on the
sequence mode(this function is effective only when the limit mode is set to
sequence mode.).
command syntax
:
COMParator:SEQuence:BIN <BIN1 low limit>,<BIN1 high limit>,
<BIN2 high limit>,…, <BINn high limit>
<BIN1 low limit>: NR1, NR2 or NR3 format
,
the low limit of BIN 1.
<BIN1 high limit>: NR1, NR2 or NR3 format
,
the high limit of BIN 1.
<BINn high limit>: NR1, NR2 or NR3 format
,
the high limit of BIN n(the
maximum value of n is 9).
Note:the low limit should be less than the high limit
e.g.
:
WrtCmd(―COMP:SEQ:BIN 10,20,30,40,50‖)
query syntax
:
COMParator:SEQuence:BIN?
return
:
<BIN1 low limit>,<BIN1 high limit>,<BIN2 high limit>,…,
<BINn high limit><NL^END>
:Secondary LIMit
is used to set the high limit and the low limit of the secondary parameter for
the comparator.
command syntax
:
COMParator:SLIMit <low limit>,<high limit>
<low limit>: NR1, NR2 or NR3 format, the low limit.
<high limit>: NR1, NR2 or NR3 format, the high limit.
Note:the high limit should be greater than the low limit, or the error message will be
prompted.
e.g.
:
WrtCmd(―COMP:SLIM 0.001,0.002‖)
query syntax
:
COMParator:SLIMit?
return
:
<NR3>,<NR3><NL^END>
:
Auxiliary BIN
is used to set the auxiliary BIN ON/OFF of the BIN Count. The state of the
auxiliary BIN can be queried.
command syntax
:
ON
COMParator:Auxiliary BIN OFF
1
0
char ‗0‘(48) is equivalent to OFF
char ‗1‘(49) is equivalent to ON .