4-20
PDW-HD1500/V1 (E)
4-7-7. IN-LIM TEST
This menu allows you to move the optical block assembly
to the inner-limit position of the disc.
n
If a cartridge is inserted, eject it.
Menu hierarchy:
[M6 : DRIVE]
→
[D0 : DRIVE MAINTENANCE]
→
[CHECK]
→
[SLIDER]
→
[IN-LIM TEST]
1. Select “IN-LIM TEST” using the
[(]
/
[)]
buttons, and
press the
[*]
button.
2. A confirmation screen appears waiting for entry of the
[SET]
button.
3. Press the
[SET]
button.
The result appears.
n
Check visually that the optical block assembly moves
to the inner-limit position.
If failed:
The following screen appears.
IN-LIM TEST
CHECK START?
OK: SET KEY
EXIT: MENU KEY
IN-LIM TEST
CHECKING...OK
EXIT: MENU KEY
IN-LIM TEST
CHECKING...ERROR
EXIT: MENU KEY
4-7-6. AUTO TEST
This menu allows you to check optical block assembly
operations and the limit sensor.
n
If a cartridge is inserted, eject it.
Menu hierarchy:
[M6 : DRIVE]
→
[D0 : DRIVE MAINTENANCE]
→
[CHECK]
→
[SLIDER]
→
[AUTO TEST]
1. Select “AUTO TEST” using the
[(]
/
[)]
buttons, and
press the
[*]
button.
2. A confirmation screen appears waiting for entry of the
[SET]
button.
3. Press the
[SET]
button.
The result appears.
If failed:
The following screen appears.
AUTO TEST
CHECK START?
OK: SET KEY
EXIT: MENU KEY
AUTO TEST
CHECKING...OK
EXIT: MENU KEY
AUTO TEST
CHECKING...ERROR
EXIT: MENU KEY