PDW-HD1500/V1 (E)
7-2
SERVO_1
OP-0
ADJUSTING...COMPLETED
EXIT: MENU KEY
5. Press the
[SET]
button.
A confirmation screen appears.
6. Open the shutter of the cartridge of the alignment disc
using the following procedure.
Be sure to close it after the adjustment.
n
Opening the shutter of the cartridge by hand is limited
to the optical drive alignment.
Do not open it for any other purpose or touch the disc
in the cartridge.
How to Open
Move the cover in the direction of the arrow while
pressing the claw. Then move the gear by hand until
the shutter is completely opened.
How to Close
Move the gear and the cover in the direction of the
arrow until the shutter is closed and the claw snaps.
7. Set the cartridge with its shutter opened so that its
guide holes are aligned with the two guide shafts of the
unit.
8. Put the weight on the cartridge.
9. Press the
[PUSH|SET]
knob.
The result appears.
10. When “COMPLETED” appears, press the
[MENU]
button.
The ADJUST screen appears.
11. If necessary, adjust the other OP in the same way.
12. Make the skew adjustment. (Refer to Section 7-3.)
Cartridge
Gear
Shutter
Open
Close
Claw
Cartridge
Weight
Guide holes
Guide shafts
SERVO_1
OP-0
SET ALIGNMENT DISC
PFD23A-RS.
ADJUST START?
OK: SET KEY
EXIT: MENU KEY