1-54 (E)
VPL-FH60
The ON/STANDBY indicator stays lit in red. The WARNING indicator blinks in red.
Error
Number of blinking
Details of the error content
Cover error
2
The filter has come off.
The top cover has come off.
Light source error
3
The light source does not light up normally.
Drop error
6
Dropping is detected.
Lens not attached error
8
The lens is not attached.
Installation angle error
9
The installation angle sensor does not operate normally.
When the installation angle is out of the usable range of this
unit
The ON/STANDBY indicator blinks in red. The WARNING indicator blinks in red.
(The indicators blink simultaneously.)
Error
Number of blinking
Details of the error content
Fan error
3
Any of the fans does not operate normally.
Wheel rotation error
4
The rotational speed of wheel has exceeded the allowable
range.
Luminance error
5
The luminance has exceeded the allowable range.
Assembling error
6
The connector of temperature sensor is disconnected.
Lens shift error
7
The time out of lens shift limit processing during startup has
occurred.
(Blinks in red.)
Blink simultaneously.
(Blinks in red.)
(Stays lit in red.) (Blinks in red.)